29
28
© 2022 Dehaco B.V. • Operation and maintenance manual DSG Demolition and Sorting grabs • No. DSG.2165.0001 • 31-01-2022
Dehaco B.V. • Kruisbaak 25 • 2165 AJ Lisserbroek (NL) •
✆
+31 (0)252 - 41 79 50 •
[email protected] • www.dehaco.nl
7. Troubleshooting
7. Troubleshooting
7. TROUBLESHOOTING
7.1 The demolition and sorting
grab does not work
7.2 Insufficient closing force
7.3 The rotate function does not work
Cause
Solution
By who?
Ensure the valve in the
Open of Close pipe
is
closed.
Open the return valve.
Operator
Broken connector blocking
Open/Close
pipes.
Replace the defective coupling components. Workshop or Dehaco/dealer service
technician
Electrical equipment in the system is faulty.
Inspect the faulty electrical equipment and
repair if necessary.
Workshop
The toggle switch is faulty.
Inspect the toggle switch and replace if
necessary.
Workshop
The magnet on the switch on valve is
damaged.
Replace the magnet.
Workshop
Cause
Solution
By who?
The pipes for
Open abd Close are swapped. Connect the cables as required.
Operator
The operating pressure is too low.
Correct the operating pressure.
Workshop or Dehaco/dealer service
technician
Cause
Solution
By who?
Rotary motor/gear unit/slewing ring/
rotation transmission defect.
Inspect the rotary motor/gear unit/slewing
ring/rotation transmission and replace the
defective parts.
Workshop or Dehaco/dealer service
technician
Cause
Solution
By who?
The oil level in the tank is too low.
Check the oil level and top up if necessary.
Operator or workshop
The pumping volume of the excavator is
too high; there is a constant amount of oil
spraying from the pressure reducing valve.
Check the speed of the excavator motor and
correct. Switch the pump on.
Dehaco service technician or an authorised
Dehaco dealer.
The pressure reducing valve is faulty or
there is a defect in the valve.
Fit a new pressure reducing manager or a
more accurate pressure relief valve.
Dehaco service technician or an authorised
Dehaco dealer.
7.4 The operating
temperature is too high
7.5 Oil leaks at hydraulic connections
7.6 Insufficient lubrication
Cause
Solution
By who?
Cap nits are loose.
Inspect the cap nuts and tighten.
Operator
Hose connections are loose.
Inspect the connections and tighten.
Operator
Cause
Solution
By who?
Interval between lubrication is too long.
Check lubrication and lubricate.
Operator