11. Electroforming Procedure in DeguDent Device:
Menu Display
• Main Menu
• Number of electrodes and Plaster
Release ON/OFF are displayed
• Coating thicknesses and sample
types are displayed
• Automatic determination and
display of calculated liquid amount,
activator and glass size
• Coating thicknesses, sample types
and resulting slots are displayed
• Liquid amount, activator and glass
size are displayed
• Visualization of sample placement
• Slots and contact detection are
displayed
• Dynamic display of time remaining
(heating the electroforming bath,
electroforming, plaster removal)
• Current bath temperature is
displayed
• Dynamic updating of the process
status
Action
Selection of
“Electroforming”
mode
Selection of
Parameter 1
Selection of
Parameter 2
Preparation
Starting
Electroforming
Step
1
2
3
4
5
User Actions
• Select “Electroforming” from
the menu
• Confirm your selection by pressing
ENTER
• Adjust the number of electrodes
• Activate/deactivate plaster release
• Press START to change the menu
• Separately adjust the coating
thicknesses of all samples
• Select all sample types
• Press START to change the menu
• Fill in the calculated goldplating bath
amount and the activator in the
specified glass
• Place the glass slide according to
what is shown in the display
• If necessary, fill with 500 ml of plaster
remover
• Press START to change the menu
• Press START to begin electroforming