Leakage control at the connection point
•
Ensure that the control knobs on the control
panel are in the OFF position.
•
Open the valve on the Gas bottle.
•
Using a small paint brush, apply some soapy
water to all the connections.
•
If there is a leak, bubbles will appear.
•
If this occurs, close the gas bottle valve .
•
Check and tighten the connections
immediately.
•
Repeat the procedure to ensure that there are
no further leaks.
1.
Hose tip-LPG
2.
Hose tip-NG
3.
Safety hose
4.
O-ring (gasket)
5.
Clamp
Caution:
Never use a naked flame
to check for gas leaks.
DANGER Risk of explosion by
damage of the safety tube!
The safety tube must not be
clamped, bent or come into contact
with hot parts of the appliance.
DANGER
Risk of explosion and
suffocation! LPG bottles must not
be stored in the house.
Gas
conversion
In order to have the appliance's gas type
changed, all the injectors must be changed and
the flame adjustment for all valves must be set
at the reduced flow rate position.
Changing the injectors
1. Take off burner cap and burner body.
2. Unscrew injectors by turning them
counterclockwise.
3. Fit new injectors.
4. Check all connections for secure fitting and
tightness.
The flames should be blue and burn
smoothly. If the flames appear
yellowish, check that the burner cap
is seated correctly or clean the
burner. Switch off the gas and let
burner cool before touching it.
Manifold
protection
plug
Manifold protector plug removal:
The manifold protection plug is inserted into the
manifold at factory level in order to protect the
manifold from being contaminated with debris.
The manifold protection plug must be removed
when the product is installed by the gas installer.
Manifold
1
Flame failure device (model dependent)
2
Spark plug
3
Injector
4
Burner
DANGER Risk of explosion or
poisoning by unprofessional
installation.
Gas conversion must
only be carried out by a registered
installer.
Unless there is an abnormal
condition, do not attempt to remove
the gas burner taps. You must call
an authorised service agent if it is
necessary to change the taps.
New injectors have their position
marked on their packing or refer to