background image

Page 10 

Safety when working with 
electricity 

x

Defective electric equipment is 
one of the major causes of 
house fires. 

x

Any work on electrical 
equipment and systems should 
only be carried out by 
authorized and qualified 
persons. 

 

IMPORTANT: 

If the gas type of the 
appliance is changed, 
then the sticker that is 
currently on the 
underside of the 
appliance that reads 
“Factory adjusted for 
LPG gas” must be 
replaced by the sticker 
“Adjusted for natural 
gas”. The new sticker 
can be found in the gas 
jet kit supplied with the 
appliance. 

 

IMPORTANT: 

If the gas type of the 
appliance is changed, 
then the rating plate that 
shows the gas type of 
the unit must also be 
changed. 

x

In case of any damage, switch 
off the appliance and 
disconnect it from the mains. To 
do this, turn off the fuse at 
home. 

x

Ensure that the fuse rating is 
compatible with the appliance. 

x

This appliance should not be 
used for warming plates under 
the grill, drying towels, dish 
cloths etc. by hanging them on 
the oven door handles. This 
product should also not be 
used for room heating 
purposes. 

x

Incorrect installation 
environments will void the 
guarantee. 

x

This appliance should not be 
used for room heating 
purposes. 

x

The manufacturer shall not be 
liable for any damage caused 
by improper use or handling.  

SAVE THESE INSTRUCTIONS

 

 

Danger of fire: Do not store items on the 
cooking surface. 

CAUTION: 

The cooking process has 

to be supervised. A short term cooking 
process has to be supervised 
continuously. 

WARNING: 

Unattended cooking on a 

hob with fat or oil can be dangerous and 
may result in a fire. 

Содержание DHG604

Страница 1: ...Page 1 DHG604 60 CM GAS HOB Cooking Instruction manual Part number 071186...

Страница 2: ...on Warning for supply voltage Caution Warning for fire hazard Useful information Important information or useful hints about usage Table of contents 1 General information 3 Overview 3 Technical specif...

Страница 3: ...burner The manufacturer strives for continuous improvement For this reason technical specifications text and illustrations in this manual are subject to change without notice Figures in this manual a...

Страница 4: ...ations may be changed without prior notice to improve the quality of the appliance Figures in this manual are schematic and may not exactly match your appliance Values stated on the appliance labels o...

Страница 5: ...for any problems arising due to the appliance not being earthed in accordance with the local regulations x If the supply cord is damaged it must be replaced by the manufacturer its service agent or si...

Страница 6: ...firm persons away from the appliance when it is in use x Only use the appliance for preparing food x Use a deep pan large enough to cover the appropriate burner x Always dry food thoroughly before pla...

Страница 7: ...only be done by authorised qualified persons who are registered LPG Gas installers x Prior to installation ensure that the local distribution conditions nature of the gas and gas pressure and the adju...

Страница 8: ...trol valve unless it s in a confined space or cellar In the event of a pan fire x Switch off the Gas supply x Smother the flames with a blanket or damp cloth x Burns and injuries are usually caused by...

Страница 9: ...rn back x In the event of a burn back where the flame burns back into the jet immediately turn off the control to the affected burner x Wait a few minutes and relight the burner in the normal manner x...

Страница 10: ...y damage switch off the appliance and disconnect it from the mains To do this turn off the fuse at home x Ensure that the fuse rating is compatible with the appliance x This appliance should not be us...

Страница 11: ...perating pressure of 2 8 3 0 kPa A suitable LPG regulator that complies with the requirements of SANS 1237 must be used The manufacturer and the seller do not accept responsibility for any damage due...

Страница 12: ...size Ventilation opening Smaller than 5 m3 min 100 cm2 5 m3 to 10 m3 min 50 cm2 Greater than 10 m3 not required In the cellar or basement min 65 cm2 Important information for the installer This applia...

Страница 13: ...ich complies with SANS 1237 must be used Permanent installation Important information for the user This appliance may only be installed by a registered LP Gas installer All registered installers are i...

Страница 14: ...ng any work on the gas installation please shut off the gas supply x Gas adjustment conditions and values are stated on labels or on type label Your appliance is adjusted for LPG gas Connecting the ga...

Страница 15: ...In order to avoid foreign substances and liquids penetrating between the hob and the counter please apply the putty supplied in the package on the contours of the lower housing of the hob making sure...

Страница 16: ...stment screw For LPG Butane Propane turn the screw clockwise For natural gas you should turn the screw counter clockwise once The normal length of a straight flame in the reduced position should be 6...

Страница 17: ...ce of your appliance for any damages that might have occurred during transportation Disposing of the old product Dispose of the old appliance in an environmentally friendly manner Refer to your local...

Страница 18: ...Place the pans and saucepans in a manner so that their handles are not over the hob to prevent heating of the handles Do not place unbalanced and easily tilting cooking vessels on the hob x Do not pl...

Страница 19: ...not press the knob for longer than 15 seconds if there was no ignition Wait for one minute and then repeat the ignition process Wok burner As a counter measure against blow out due to fluid overflows...

Страница 20: ...iance to cool down before you clean it Sugar based foods such as thick cream and syrup must be cleaned promptly without waiting the surface to cool down Otherwise glass ceramic surface may be damaged...

Страница 21: ...d remove the pot stands burner caps and burner bodies 1 Insert the socket into the central tube of the burner so that it locates over the brass gas jet at the bottom of the tube 2 Gently loosen the br...

Страница 22: ...The lighting procedure has not been followed correctly Follow the correct lighting procedure The flame is yellow Pots and pans are stained The burners are dirty or wet Clean dry the burner components...