DEFENDERTECH® FOG GENERATOR DATA SHEET ETHERNET VERSION 

WITHOUT INTEGRATED ALARM CONTROL UNIT 

FEATURES AND PERFORMANCE 

DT-400Lan 

 

Fog dispensed in 60”  

415 m3 effective continuous 

 

Fog dispsensing time 

1-60 sec

 

Forced breack time 

From  5 a 20 min

 

Total dispensing time 

5 min (with a full tank)

 

total quantity dispensed 

2.075 m3 (with a full tank)

 

Fog maintenance fuction 

NO

 

Heating time (100%) 

Max 25 min

 

Reaction time 

200 MS

 

Power Supply 

220 volts

 

Nominal Power consumed when armed 

600 watts

 

Power consumption management 

NO

 

Power consumed in Stand-by 

120 mA

 

DimensioniDimension 

380 X 380 X145 MM

 

Built-in backup battery 

Yes (nr. 2 x 1 3A)

 

Burner autonomy without mains power 

At least one 60” shot can be made within 1 hour

 

Fault indicator system 

Yes

 

liquid level indicator 

Yes

 

Anti-opening tamper-proof device 

No

 

12 Vdc output fro external sensor 

500 mA

 

Colour 

Withe, Silver, Gold, Anthracite

 

Weight 

10 Kg with a full tank

 

Tank Capacity 

0,5 LT

 

 

MECHANICAL OPTIONS 

 

Nozzles for directing the Fog jet: 1×0° 1×45° 1×90° 3×0° 3×45° 2×0°/45° 

 

Nozzles extension, lengh adjustable up to 200 mm. 

 

Nozzles extension, lengh adjustable up to 500 mm. 

 

Fog jet diversion kit, passes through the wall behind the equipment,  

 

Fog jet split and diversion kit, 50% passes through the wall behind the 
equipment, 50% at the front (to cover 2 adjacent rooms) 

● 

 

ELECTRONIC FUNCTIONALITY 

 

Event log saved on the device and on the Web Server 

 

“Safew shoot” function (requires double consent to shoot)  

 

Automatic update of date and time referring to two programmable NTP Web 
Servers 

 

“Device Armament Block” function on a programmable time band 

 

Monitoring, drive and device programming via Web (LAN or Wi-fi) or PC 

     ● (4) 

 

Physical outputs for signaling: status, lev. Liquid, burner ready, shot in 
progress 

 

3 Different leves of password-protected access that can be changed 

 

“Unlimited Tank” function (allows the withdrawal of fluid from larger tanks) 

 

 

INPUTS – OUTPUTS – SIGNALS 

 

1 Input for fog activation (armament) 

     ● (2)

 

NC – NP and – OR progrannable inputs for shot activation 

     ● (2)

 

Programmable reley outputs for signaling liquid level and device failure 

     ● (2)

 

Outputs OC for burner signaling ready-activation shot in progress  

 

6 LED lights indicating operation/failure 

● 

1 buzzer for operation/failure 

 

● 

1 Ethernet connector for remote monitoring and management of the device 

● 

1 WI-FI card connector (optional) for monitoring and device control 

● 

 

Содержание DT-400Lan

Страница 1: ...Manual of installation and maintenance Fog Generators DEFENDERTECHDT 400Lan...

Страница 2: ......

Страница 3: ...e power supply of the appliance must be supplied through a special switch or plug in order to allow it to be switched off Danger of burns the components of the appliance are subject to heating do not...

Страница 4: ...ct then this will have to report their presence to the Producer on penalty of forfeiture within one week of discovery 4 The Customer provided that he has provided a timely description of the data cont...

Страница 5: ...igation to display The legislation provides for the obligation to post in the access route of the premises a notice that signals the presence of a Fog Generator Use the adhesive label supplied with th...

Страница 6: ...zles extension lengh adjustable up to 500 mm Fog jet diversion kit passes through the wall behind the equipment Fog jet split and diversion kit 50 passes through the wall behind the equipment 50 at th...

Страница 7: ...ling For wall installation DO NOT TURN THE APPLIANCE correct position as shown in the photo Use 4 dowels Fischer of 10 mm of the type suitable for the wall where the machine will be installed In the c...

Страница 8: ...Description DT 400Lan Control Card...

Страница 9: ...the level is in reserve at least 60 of autonomy available It is recommended to bring the contacts to the control panel and create an unarmed area for signaling purposes Note This contact can be used t...

Страница 10: ...there is also a signal on FOG or FOG2 which must always be at rest during this phase so keep them at rest and re arm If desired it is possible to change the contact activation mode to OPEN N C turnin...

Страница 11: ...p per second At the end of the waiting time if the 2nd signal on the other input has not arrived the pre alarm will be reset Handbrake or Safe Firing Function Activating this function the Fog2 input t...

Страница 12: ...X X X X FORCED PAUSE TIME 5 MIN X X X X X OFF OFF X X X 10 MIN X X X X X ON OFF X X X 15 MIN X X X X X OFF ON X X X 20 MIN X X X X X ON ON X X X Not active for 400plus X X X X X X X X OFF X X x X X X...

Страница 13: ...DIP3 DIP4 DIP5 DIP6 DIP7 DIP8 DIP9 SETTING LACK OF NETWORK SIGNALING OFF OFF X X X X X X X X LACK OF NETWORK SIGNALED ON STATE RELAY ON ON X X X X X X X X LACK OF NETWORK NON SIGNALED ON STATE RELAY...

Страница 14: ...nctions of the Menus 1 and 2 you will have to program them simultaneously starting from those of the menu 1 activate the DIP10 and then the DIP corresponding to the desired functions of the Menu2 DIP...

Страница 15: ...PAUSE STATE FIXED ON THE APPLIANCE IS IN THE FORCED PAUSE STATE it will ignore every firing commands untili its end ONE FLASH FOR EVERY RIARMAMENT OF THE MACHINE FAILURE LED6 RED TURNED OFF NO ALLARM...

Страница 16: ...mperature is lower than that needed to dispense dry and quality fog The forced pause phase is active used to avoid excessive shots in a room already saturated with fog The Safe Firing function is acti...

Страница 17: ...ed free of charge by making a request complete with social data at the following address info defendertech eu IP ADDRESS AND PASSWORD RESET PROCEDURE 1 Disconnect ARM and FOG 2 Switch the appliance of...

Страница 18: ...s incorrect reset the error by operating the DipSwitch no 5 if it persists the appliance will not work until it is replaced by the service DefenderTech LACK_NETWORK_ALARM self restoring lack of electr...

Страница 19: ...the liquid level to the 100 acting on DipSwitch nr 4 TECHNICAL INSTALLATION START Once the machine is connected to the mains activate the buffer battery connecting the flying cable to the respective f...

Страница 20: ...following is prescribed to Replace the buffer batteries 2x12V 1 3 are wired in series Arm the appliance by measuring voltage and absorption on the 230V mains Perform a full 60 second shot using water...

Страница 21: ...s Lan 801 DT 1600plus Lan 1601 DefenderTech Fog Generator Device Fog Genrator for safety applications They comply with the European Community Directives Low Voltage 2004 108 CE Electromagnetic Compati...

Страница 22: ...rom the label obligation directive C E E HAZARD IDENTIFICATIONS No specific danger can be found in the use of the effects PHYSICAL AND CHEMICAL PROPERTIES Physical state liquid Appearance and color li...

Страница 23: ...12 06 2010 Tek Group S r l...

Страница 24: ...www defendertech eu info defendertech eu Tel 39 0721 1626113 Fax 39 0721 0731145...

Отзывы: