When the signal is interrupted within the firing time, dispens is immediately stops and the forced
pause time is also skipped.
The parameters set in the factory are:
Shot time: 60 ''
Forced pause: 15 '(used to prevent unnecessary shooting once the environment is saturated)
Admission: N.O. (Normally Open)
DIP-Switch configuration ON 1-2-7
FOG2
(N.A. by default but modifiable N.C.)
This input, as for factory programming, behaves like the "FOG" input (in OR), through the "menu
2" of the special functions it is possible to modify the operating logic.
"And-Fog2" Function
By activating this function, the shot will be executed ONLY if FOG and FOG2 will receive an input in
a 15-minute time window and the waiting period will be scanned with a beep per second.
At the end of the waiting time, if the 2nd signal on the other input has not arrived, the pre-alarm
will be reset.
"Handbrake" or "Safe Firing" Function
Activating this function, the Fog2 input takes on the task of preventing (accidental) firing.
- If a negative signal is present on FOG2, the shot will not be allowed.
- If the signal arrives while the shot is in progress, it will be ignored.
- If a signal is present at the Armament time this will be ignored, allowing ARM.
- If DIP3 is "ON", ie the inputs are set to "NC" mode, FOG2 will only be at rest when it is grounded
(same logic as ARM and FOG).
CAUTION !!!!!!
NEVER DISPENSE FOG IN A AIR-CONDITIONED AMBIENCE
The air-conditioning process accelerates the abatement of humidity that "supports" the substance
that creates a fog effect, thus increasing the risk of leaving oily residues on surfaces.
If the air-conditioning is necessary, this risk can be avoided by ventilating the ambience.