10
3. Record measurements for each hole in the project:
To record probe measurements, touch the circle
corresponding to the hole and touch the
Measure
button to
record the Relative Humidity and Temperature within the
corresponding hole.
Ambient Relative Humidity and Air Temperature (above the hole)
can be recorded using a spare
PosiTector CMM IS
probe or
PosiTector DPM Advanced
instrument. The ambient instrument
being used is specified within the
Project setup
(pg. 6). Select
Measure, and then Ok to store the displayed values. Alternately,
a relative humidity and temperature value can be entered
manually.
Repeat
Step 3
for each hole in the project. Once readings have
been recorded for all holes in the project, professional reports can
be generated that conform to ASTM F2170. Select
REPORT
from
within the Project to automatically generate the report.
More detailed instructions on using the
PosiTector App
is
available in the Help File, located at www.defelsko.com/app-help
NOTE: