6
POWER SUPPLY MODE
When the charger is turned off the button can be pressed until the LED shines one by one in a regular bottom to the top cycle. The charger will be in power
supply mode regardless of the battery voltage after it has been turned on, so it can be used to change the battery of the car without loosing car settings/
data. In this mode, the charger supply 13.7V and max 35 Amp. If the output short circuit in this mode, the charger will go into error mode. You should
press the power button to turn off the charger, correct the problem, then restart the charger (go to charger or power supply mode).
POST ANALYSIS
The charger analyses the battery again after the charging phase. Post analysis can detect batteries with a short circuit in individual cells. This cannot be
detected in the pre analysis. If the battery voltage drops below 12V within 2min, the charger will go into error mode and the red warning triangle will start
to flash. The charging sequence will be stopped.
LONG-TERM CHARGING
After the battery is fully charged, the charger will deliver 13,6V with a maximum of 35A. This is indicated by all battery LEDs slowly pulsating.
TEMPERATURE BASED VOLTAGE COMPENSATION
The charger automatically adjusts the charging voltage to the correct level according to the ambient temperature. The default ambient temperature
is 25°C. Voltage is reduced for higher ambient temperatures and increased for lower ambient temperatures. The correct amount is ±0.03V/°C. Max
temperature compensate charging voltage is 15.3 V
USE
Read the user guide carefully. If there are any uncertainties, please contact DEFA or a qualified person.
For installation of the wall bracket, see E on page 4.
Connect red clamp to (+) and black clamp to (-) or the connection point recommended by the vehicle manufacturer. The charger is intended for use with
lead/acid, AGM, EFB, GEL and Lithium batteries. The battery manufacturer’s recommendations shall always be taken into consideration.
Connect the AC mains cable to the charger. Push the power button once. See figure 2, page 2. The charger will start up and initialize the pre-analyze
process. To turn of the charger, push the power button again.
NOTE:
To make sure the correct charging voltages are applied to battery the charging cables must not be shortened or made longer.
NOTE:
See figure 6 on page 4. An optional hook can be installed. Do not add other weight to this hook than the charger with cables.
MAINTENANCE
Make sure that the connector on both charger and cables (C page 2) are free from moist and dirt before using the charger. All batteries should be
inspected monthly as a minimum to achieve the best possible safety. The charging process is in such way that the batteries remain fully charged without
further water consumption than normal evaporation.
If future needs require a software update of the charger, it can be done through the micro-USB port at the end of the charger.
See D page 2. Necessary information will be given along with the software.
WARRANTY
The guarantee applies to faults in production and materials for 2 years from date of purchase. The customer must deliver the product back to the place
of purchase together with the receipt. The guarantee shall cease to apply if the charger is handled negligently, opened or repaired by someone other than
DEFA or an authorized representative of DEFA. DEFA has no other guarantee than this and will not be responsible for other costs than those referred to, i.e.
no possible additional costs. Neither is DEFA bound by any other guarantee.