background image

Boat

GB

1.5 EMERGENCY DEACTIVATION OF THE ALARM

Use the button on the PIN code panel to enter the four fi gures on your PIN code card.
1. Turn on the ignition.
2. Press the button on the PIN code panel as many times as

    the fi rst fi gure in the PIN code.  (If the PIN code is, for

    example: 3 – 1 – 5 – 2, fi rst fi gure is 3 and the button is 

    pressed 3 times).
3. Then wait while the LED lights to show that the

    fi rst fi gure has been 
4. Press the button on the PIN code panel as many 

    times as the second fi gure in the PIN code, and

    wait for receipt. 
5. Continue in the same way for the third and fourth 

    fi gures.
After the fourth fi gure has been entered, the alarm will 

turn off after a few seconds, as long as the correct PIN 

code has been entered. If the wrong code is entered, 

wait min. 10 sec. before trying again. Start at point 2.

1.4 TURNING ON YOUR ALARM (ACTIVATION)

You deactivate the alarm with a short press on button 1.
The  boat’s  lights  fl ash  briefl y  twice. The  LED  on  the  PIN  code 

panel stops fl ashing. The alarm is deactivated.

NB! 

It is important that an alarmed hatch is not opened, or the igni-

tion turned ON for 4 minutes after deactivation. See the chapter on 

reactivation.

54

� � �

� �

� �

� � �

� � � � �

� � � �

� � � �

� � � � � � � � � � � � �

� � �

� �

� � �

� � �

� �

� � � � � � �

� � � �

� � � � � � � � �

� �

� � �

� � �

Button 1

1.6 WARNINGS OF ALARMS TRIGGERED DURING 

THE LAST PERIOD OF ACTIVATION

If the alarm has been trig-

gered since it last was acti-

vated,  the  alarm  will  warn 

you when the fi rst alarmed 

hatch  is  opened  following 

deactivation.  It  warns  you 

with two short blasts of the 

siren and/or horn.  

Содержание BG600

Страница 1: ...B G 6 0 0 Bruksanvisning Käyttöohje User Manual www defa com Boat ...

Страница 2: ...otect users against problems that can occur when the installation work is shoddy The functions of the alarm and its electrical connections should be checked once a year in order to achieve reliable operations It is important that you as the boat s owner read this manual carefully The BG600 is manufactured by DEFAAS www defa com TABLE OF CONTENTS How to use your BG600 53 Turning on your alarm activ...

Страница 3: ...tton 1 The boat s lights flash once for 2 seconds The LED on the PIN code panel begins to flash The alarm is activated NB The ignition must be OFF before you can activate the alarm NB The alarm can only be triggered sounding the alarm five seconds after activation 53 The range can vary Local radio disturbance can affect the range 1 HOW TO USE YOUR BG600 1 2 TEMPORARY DISCONNECTION OF SENSORS If you f...

Страница 4: ...red the alarm will turn off after a few seconds as long as the correct PIN code has been entered If the wrong code is entered wait min 10 sec before trying again Start at point 2 1 4 TURNING ON YOUR ALARM ACTIVATION You deactivate the alarm with a short press on button 1 The boat s lights flash briefly twice The LED on the PIN code panel stops flashing The alarm is deactivated NB It is important that...

Страница 5: ...rned of by a short blast of the siren horn during activation can be disconnected 55 1 7 REACTIVATION If you turn the alarm off but do not open an alarmed hatch or turn on the ignition the alarm turns on again 4 minutes after deactivation This is a function that protects against inadvertant deactivation NB The hatch does not have to remain open It is enough to open and close the hatch because the a...

Страница 6: ...24 hour alarms is sent per 24 hour alarm input per alarm activation In other words when you receive a water level alarm for example the system will block transmission of more water level alarms until the ignition is turned ON does not have to remain on or the alarm is activated does not need to remain activated The system does not however block warning of other alarms connected to other 24 hour al...

Страница 7: ...gures on your PIN code card 1 Turn off the alarm and turn the ignition on 2 Press the button on the PIN code panel as many times as the first figure in your PIN code If the PIN code is for example 3 1 5 2 first figure is 3 and the button is pressed 3 times 3 Then wait while the LED lights to show that the first figure has been received 4 Press the button on the PIN code panel as many times as the second...

Страница 8: ...nd changes 1 second after the button is pressed the batteries should be replaced They should be replaced within 14 days The batteries have a normal lifetime of 1 year NB The battery warning can also be triggered if the remote control is stored cold This is because batteries have lower voltage levels in cold conditions The batteries are type CR 1220 and can be bought from boat alarm installers or i...

Страница 9: ...Telephone chapter HINT You can change PIN code 3 to the same as PIN code 1 to make it easier to remember This gives you only one PIN code to remember Remember to keep this PIN code unavailable for unauthorised persons Important The serial number on the central unit will allow DEFA to find PIN code 1 if you should lose it or forget it If you choose to change PIN code 3 to something dif ferent from P...

Страница 10: ...to be topped up at least once per year As the SMS function will not work with an empty card the balance on the card must be regularly checked NB When the SIM card has been acquired the PIN control must be turned off before the card is installed in the alarm central unit You do this by first installing the SIM card in a mobile phone then selecting PIN control OFF The method depends on the telephone ...

Страница 11: ... always begin with the name of the boat NAME message Example Dorothea Water level Alarm 11 ABOUT COMMANDS CHANGING THE SMS SECURITY CODE Command OLD CODE P NEW CODE NEW CODE E g 0000 P 3D2k 3D2k Response NEW PIN OK NB The security code must consist of 4 characters The security code may be LARGE and small letters or random characters e g 3D2k NB The alarm is caps sensitive ADD AMEND TELEPHONE NUMBE...

Страница 12: ...hone number T2 telephone number T3 telephone number E g T1 46705008999 T2 000000000000 zeroes if no number T3 000000000000 ACTIVATE BOAT ALARM Command PIN CODE ON A Example 26W1 ON A Response SYSTEM ON BATT voltage V TEMP temperature C Example SYSTEM ON BATT 12 7V TEMP 9C NB The alarm will NOT activate if the ignition is on DEACTIVATE THE BOAT ALARM Command PIN CODE OF A Example 26W1 OF A Response...

Страница 13: ...ing on your boat s installation you can only see 3 or fewer control outputs in the alarm response DO NOT use control outputs for functions that could lead to personal injury or damage to property DEACTIVATE CONTROL OUTPUT Command PIN CODE OF 1 4 Example 26W1 OF 2 Response ON control output no OFF control output no Example ON OFF 1 2 3 4 STATUS OF CONTROL OUTPUT Command PIN CODE S2 Example 26W1 S2 ...

Страница 14: ...ored at the SMS exchange for maximum 48 hours BURGLAR ALARM Alarm message ID triggered alarm loop ALARM Example DOROTHEA DECK HATCH ALARM BATTERY ALARM low voltage Alarm message ID BATT ALARM voltage V Time UTC Date Example DOROTHEA BATT ALARM 11 4V 12 22 UTC 21 12 03 Time and date are only shown if GPS is installed on the alarm MOTION ALARM with GPS accessory Alarm message ID GPS ALARM POS latitu...

Страница 15: ...s and or horn do not work when the alarm is triggered The light signal and horn are protected against short circuits When they are overloaded they automatically turn themselves off Contact your installer to check power consumption The telephone module does not send SMS messages If a top up card is used in the telephone module check that there are funds in the card and that it is activated Check th...

Страница 16: ...ulse Steady SENSITIVITY GLASS BREAKAGE Low Normal High NOTE HOW THE ALARM IS PROGRAMMED Location of the fuses Alarms serial number TELEPHONE SMS TYPE Normal SMS Direct view BOAT ID BATTERY ALARM LEVEL ALARM NUMBER 1 ALARM NUMBER 2 ALARM NUMBER 3 EMERGENCY NUMBER 13 PROGRAMMING ...

Страница 17: ...INSTANT TIMER OFF TIMER ON TIME SEC MIN BLOCKED WHEN ALARM ACTIVATED BLOCKED WHEN IGNITION ON NOTE HOW THE CONTROL OUTPUTS ARE PROGRAMMED CONTROL OUTPUT 3 GROUNDED STATUS OUTPUT DEACT STATUS OUTPUT ACT SMS BUTTON VARYING INSTANT TIMER OFF TIMER ON TIME SEC MIN BLOCKED WHEN ALARM ACTIVATED BLOCKED WHEN IGNITION ON CONTROL OUTPUT 4 GROUNDED STATUS OUTPUT DEACT STATUS OUTPUT ACT SMS BUTTON VARYING IN...

Страница 18: ...control outputs for controlling e g heaters or spotlights via SMS and or BG600 remote control P GPS Positioning requires GPS accessory Attack emergency alarm Requires GPS accessory and emergency transmitter P Short circuit protection 1 All outputs are protected against short circuit Short circuit protection 2 After a short circuit disconnection of the boat s battery the alarm returns to its previo...

Страница 19: ......

Страница 20: ...AB S 191 81 SOLLENTUNA SVERIGE Manufactured by DEFAAS Norway Boat Distributor Finland OY KAHA AB Pl 117 FIN 01511 VANTAA FINLAND AK 09 05 8199 A www defa com Distributor Norway AS Sørensen og Balchen PB 134 HOLMLIA N 1203 OSLO NORGE ...

Отзывы: