Boat
GB
63
BOAT ALARM STATUS:
Command:
[PIN CODE]
S1
Example
:
26W1 S1
Response:
SYSTEM <ON:OFF>
BATT XX V
TEMP YY C
Example
:
SYSTEM OFF
SENSOR OFF *
BATT 12,2V
TEMP -5C
ACTIVATE CONTROL OUTPUT:
Command:
[PIN CODE]
ON
[
1
-
4
]
Example:
:
26W1 ON 2
Response
:
ON <control output no>
OFF <control output no>
Example:
:
ON 2
OFF 1 3 4
* Sensor statuses are only shown when they are turned off
NB!
Outputs reserved for alarm functions (e.g. sirens) will not execute a command via SMS.
Depending on your boat’s installation, you can only see 3 or fewer control outputs in the alarm
response. DO NOT use control outputs for functions that could lead to personal injury or
damage to property!
!
DEACTIVATE CONTROL OUTPUT:
Command:
[PIN CODE]
OF
[
1
-
4
]
Example
:
26W1 OF 2
Response:
ON <control output no>
OFF <control output no>
Example:
:
ON -
OFF 1 2 3 4
STATUS OF CONTROL OUTPUT:
Command:
[PIN CODE]
S2
Example
:
26W1 S2
Response:
ON <control output no>
OFF <control output no>
Example
:
ON 3
OFF 1 2 4
GPS POSITION (Accessory)
Command:
[PIN CODE]
L
Example:
:
26W1 L
Response:
POS <latitude>N <longitude>E
<speed>knt <heading>D
<time> UTC
Example
:
POS 5919.60N 01804.30E
34knt <125D
13:43 UTC