Installation in ducting version
Cut a hole in the bottom of the pensile cupboard in order to settle the appliance (Fig.4).
Install the wiring system and prepare the air venting hole.
Insert the appliance in the hole (Fig. 4)
Tighten the 2 screws inside the appliance (Fig. 5) until it fits snug on the bottom of the wall unit. Avoid tightening the two screws
with excessive force.
To get optimal conditions the air venting pipe should: be as short as possible, have the lowest number of bends (max bende angle:
90°), be made of material approved by local authorities (according to the State), have its inner side as regular and smooth as
possible. It is moreover recommended to avoid drastic changes of pipe cross section (recommended diameter: 150 mm).
L’apparecchio è dotato di una riduzione 150-125cm.
Using a proper pipe, connect the air venting flange of the apparatus to the air venting hole you made beforehand.
Make the electrical connection of the hood by means of the power supply cable.
FUNCTIONING OF THE APPARATUS
Depending on the model, the unit is equipped with the following controls:
DHG356XP, DHG376XP, DHG377XP, DHG386XP
CONTROLS - Fig. 6:
A - Light ON/OFF switch
B - Motor ON/OFF - I speed switch
C - II speed switch - Pressing once more the timer starts working: it will turn the motor OFF after a 10’ working time:
the led blinks for all this time
D - III speed switch - The timer works as for switch C
E - IV speed switch - The timer works as for switch C.
At the end of a working time of about 30 hours, all the leds blink all together to tell that the grease filters must be cleaned. After
the cleaned filters are on again, press one of the three speed switches to allow the counting to start again.
DHG316XP
CONTROLS - Fig. 7:
A - Light ON/OFF switch
B - Motor ON/OFF - I speed switch
C - II speed switch
D - III speed switch
E - motor on light.
Fig. 5
Fig. 6
Fig. 7