Dedicated Micros ©2007
Domes
Installation
The ICE dome camera can be mounted in two ways: ceiling mount for installation into a tile ceiling;
surface mount for installation directly to a hard surface or mounting structure.
Parts Supplied
•
2 x Plastic anchors
•
2 x 80 mm (3”) screws
Parts Not Supplied
•
Optional video service lead (part number DM/ICED-SERV)
Surface Mount Ceiling Mount
Surface Mount Installation
Refer to the Quickstart section for more information.
1
To remove the dome cover, rotate it counter-clockwise and gently pull it away from
the camera body. The inner liner can now be removed.
2
Using the template supplied at the rear of this manual, mark and drill the holes
required for fixing. Using the two 80 mm mounting screws, attach the dome camera
to the surface as shown. Do not over tighten the fixing screws. The screws can
be used on their own if the surface is of a suitable material (e.g. wood), but plastic
anchors must be used where the surface is of brick or masonry construction. Run
the power and video cables to the camera. Cables may be fed through the ceiling
or through the cutout in the side of the camera shroud. Remove the cutout with a
sharp knife and use a round file to smooth the edges if necessary.
3
Connect the video to either the BNC at the end of the flying lead or directly to the
BNC. Use only one of the BNC connectors to connect video.
4
Connect the power to the power terminals. These cameras are designed to operate
from a 12V DC or 24V AC power supply. Connections and polarity are indicated
next to the terminals. The power supply must be a UL Listed, Class 2 isolated type.
Warning:
This camera is a Class 2 device and therefore does not have an earth connection in the
power cord.