REG:2F:0C – EVC_FFR – Frame Filter Rejection Counter
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
- - - -
EVC_FFR
- - - -
0
The bits of the EVC_FFR register are described below:
Field
Description of fields within Sub-Register 0x2F:0C – Frame Filter Rejection Counter
EVC_FFR
reg:2F:0C
bits:11–0
Frame Filter Rejection Event Counter. The EVC_FFR field is a 12-bit counter of the frames
rejected by the receive frame filtering function. This is essentially a count of the reporting of
AFFREJ events (in
Register file: 0x0F – System Event Status Register
NB: For this counter to be active, counting needs to be enabled by the setting the EVC_EN bit
in
Sub-Register 0x2F:00 – Event Counter Control
-
bits:15–12
The remaining bits of this register are reserved.
7.2.48.7
Sub-Register 0x2F:0E
– RX Overrun Error Counter
ID
Length
(octets)
Type
Mnemonic
Description
2F:0E
2
RO
EVC_OVR
RX Overrun Error Counter
Register file: 0x2F – Digital Diagnostics Interface
, sub-register 0x0E is the RX Overrun Error counter.
REG:2F:0E – EVC_OVR – RX Overrun Error Counter
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
- - - -
EVC_OVR
- - - -
0
The bits of the EVC_OVR register are described below:
Field
Description of fields within Sub-Register 0x2F:0C – Frame Filter Rejection Counter
EVC_OVR
reg:2F:0E
bits:11–0
RX Overrun Error Event Counter. The EVC_OVR field is a 12-bit counter of receive overrun
events. This is essentially a count of the reporting of RXOVRR events in
. The EVC_OVR will be incremented once for each RX frame
discard that happens while an overrun condition persists.
NB: For this counter to be active, counting needs to be enabled by the setting the EVC_EN bit
in
Sub-Register 0x2F:00 – Event Counter Control
-
bits:15–12
The remaining bits of this register are reserved.
7.2.48.8
Sub-Register 0x2F:10
– SFD Timeout Error Counter
ID
Length
(octets)
Type
Mnemonic
Description
2F:10
2
RO
EVC_STO
SFD Timeout Error Counter