DW1000 User Manual
© Decawave Ltd 2017
Version 2.12
Page 162 of 242
7.2.43.7
Sub-Register 0x2A:0C
– TC_PGTEST
ID
Length
(octets)
Type
Mnemonic
Description
2A:0C
1
RW
TC_PGTEST
Transmitter Calibration –Pulse Generator Test
Register file: 0x2A – Transmitter Calibration block
, sub-register 0x0C is an 8-bit configuration register for use
in setting the transmitter into continuous wave (CW) mode. This CW mode is employed during the crystal
trimming operation which may be done at module manufacturing stage as part of calibrating the crystal
oscillator’s operating frequency. At all other times, for normal operation, the value in this register should be
left in its default power on value of 0x00.
Table 41:
Sub-Register 0x2A:0C – TC_PGTEST values
MODE
8-bit value to program to
Normal operation
0x00
Continuous Wave (CW) Test Mode
0x13
For more details of crystal trimming please refer to section
8.1 – IC Calibration – Crystal Oscillator Trim
7.2.44 Register file: 0x2B
– Frequency synthesiser control block
ID
Length
(octets)
Type
Mnemonic
Description
0x2B
-
-
FS_CTRL
Frequency synthesiser control block
Register map register file 0x2B
is the frequency synthesiser control block. Its main functionality is the
generation of the carrier frequency necessary for the operating channel. It contains a number of sub-
registers. An overview of these is given by Table 42. Each of these sub-registers is separately described in
the sub-sections below.
Table 42: Register file: 0x2B – Frequency synthesiser control block overview
OFFSET in Register 0x2B
Mnemonic
Description
0x00
FS_RES1
Frequency synthesiser – Reserved area 1
Frequency synthesiser – PLL configuration
Frequency synthesiser – PLL Tuning
0x0C
FS_RES2
Frequency synthesiser – Reserved area 2
Frequency synthesiser – Crystal trim
0x0F
FS_RES3
Frequency synthesiser – Reserved area 3