SI-3
™
U
ser
’s M
anual
29
Set speed alarm
Send ASCII A,XXX,<CR>
Where XXX = speed alarm in ASCII format
Radar responds back with ASCII “OK”,<LF>,<CR>
Set protocol
Send ASCII P,XX,<CR>
Where XX = serial port protocol 00 to 99
XX = 00 -> none
XX = 01 -> standard output for that model
XX = 02 -> FFT output
XX = 03 -> debug
Radar responds back with ASCII “OK”,<LF>,<CR>
Set baud rate
Send ASCII B,X,<CR>
Where X = baud rate selector number in ASCII format
X = 0 -> Baud rate set to 1200
X = 1 -> Baud rate set to 2400
X = 2 -> Baud rate set to 4800
X = 3 -> Baud rate set to 9600
X = 4 -> Baud rate set to 19200
X = 5 -> Baud rate set to 34800
X = 6 -> Baud rate set to 57600
X = 7 -> Baud rate set to 115200
Radar responds back with ASCII “OK”,<LF>,<CR>
Note: Settings will not be used until next power-on cycle .
Poll speed
(only available if Radar is configured for polled mode)
Send ASCII *P<CR> or *<CR>
Radar responds with speed update