SI-3
™
U
ser
’s M
anual
15
• When a serial protocol is running and a command is
sent to the SI-3™, the SI-3™ does receive and perform
the requested function . However, the returned "OK"
may be inserted anywhere in the data stream and
the resulting action on the host computer can not
be guaranteed . Example: The protocol is sending out
"123 .4" If a command is sent to the SI-3™, the response
may be 12OK3 .4" . For this reason it is recommended
that the "Stop" command be sent prior to any change
in serial protocol if a serial protocol has been selected
previously .
4.14 Start and Stop Output Buttons
These buttons are used to start and stop the continuously updated
serial protocol . Any configured Serial Protocol will resume periodic
data transmission after a power-cycle . The Stop command is used to
temporarily stop the periodic data transmission . This Stop state is not
retained after a power-cycle . The Clear Window button will clear the
output window .
4.15 Radar On/Off button
The Radar On / Off buttons turn the radar transmitter on and off .