GS3
4
CONNECTING SENSORS
ProCheck readers. Below is a diagram showing the wiring configu-
ration for this connector.
Figure 1: Stereo Plug
4.3
Connecting to a Non-Decagon Logger
GS3 sensors may be purchased for use with non-Decagon data log-
gers. These sensors typically come pre-configured with stripped and
tinned (pigtail) lead wires for use with screw terminal.
Refer to your distinct logger manual for details on wiring.
Our integrator’s guide gives detailed instructions on connecting the
GS3 sensor to non-Decagon loggers. Please visit www.decagon.com/support
for the complete integrator’s guide.
Figure 2: Pigtail Wiring
GS3 sensors with the stripped and tinned cable option can be made
with custom cable lengths (up to 1000 ft) on a per-foot fee basis.
This option gets around the need for splicing wire (a possible failure
point). Connect the wires to the data logger as shown, with the
supply wire (white) connected to the excitation, the digital out wire
(red) to a digital input, the bare ground wire to ground as seen below.
11