Provisions to which the product conforms: 

 

Product: Roomheater fired by solid fuel as covered under the scope of the standards listed. 
                           Intended use: Space heating in residential building. 

Characteristic 

Performance  

Report 

Fire Safety  

Satisfies 

 

 
 
 
Emission of combustible 
products and Thermal 
output/Efficiency 

Dartmoor 5 Inset- STDFDA5I  
Co @ 13% 0² Wood 0.35% Ancit 0.40% 
5Kw @ 83.3% Wood – 4.7Kw @ 73.2% Ancit 

 
6700/1 

Dartmoor 5- STDFDA5/ STDFFOH/ STDFFOL 
Co @ 13%  0² Wood 0.38% Ancit 0.40% 
5Kw @ 81.9% Wood -5Kw @ 70.7% Ancit

 

 
6931-1 

Dartmoor W5- STDFDAW/ STDFHU 
co@ 13% 0² Wood 0.38% Ancit 0.46% 
5Kw @ 80.6% Wood -5Kw @ 76.0% Ancit

 

 
60020/4- SE 

Dartmoor 6- STDFDA6 
Co @ 13% 0²  Wood 0.38% Ancit 0.46% 
6Kw @ 77.8% Wood - 6Kw @ 73.6% Ancit

 

 
60020-3 

Dartmoor 8- STDFDA8 
Co@ 13% 0² Wood 0.17% Ancit 0.18% 
8Kw @ 74.9% Wood – 73.6% Ancit

 

 
60020/1 

Release of dangerous 
substances 

None 

 

Surface temperature  

Satisfies 

 

Mechanical resistance (to 
carry a chimney/flue) 

Maximum weight to be supported 30Kg    

 

 

Test laboratory: 0692 
 

Name: M.P Chew   

 

 

 

 

 

Signature: 

               

 
Position: Technical Director (s)  

 

 

 

Date: 24

th

 September 2012 

Содержание Dartmoor Baker 8

Страница 1: ...ractor fan in the same room or space as the appliance the extractor fan could cause the stove not to function properly and pull dangerous fumes into the room This must be checked by a trained qualifie...

Страница 2: ...y two thirds the way down Dampers Left Open Operation with the air controls or appliance dampers open can cause excess smoke The appliance must not be operated with the air controls appliance dampers...

Страница 3: ...an ash clean attachment which can be plugged into your vacuum cleaner Please note If there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occ...

Страница 4: ...w unwanted cooking smells out of the oven and into the chimney Do not block this vent off The top plate can be used as a cooking surface with the hottest area being near the back Please note if you do...

Страница 5: ...ult finding If the stove starts emitting fumes into the room 1 Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislo...

Страница 6: ...or all stoves of 5 kilowatts and over or meet current building regulations Stoves must be fitted to BS8303 BS6461 PT1 2 1984 building regulations All local regulations including those referring to nat...

Страница 7: ...oved to facilitate cleaning through the stove Hearth Surround and Register Plate The stove must stand on non flammable material at least 12mm thick 1 2 The hearth must extend at least 225mm in front o...

Страница 8: ...15 C Dean Forge Dartmoor Baker 8 Solid Fuel Ancit 320 C Flue Gas Mass Flow Stove Types Flue gas mass flow gs Dean Forge Dartmoor Baker 8 Wood Burning 7 2 Dean Forge Dartmoor Baker 8 Solid Fuel Ancit 7...

Страница 9: ...taken into account Please Note Extractor fans when operating in the same room or space as the appliance may cause problems Air vent inlet grills must not be inadvertently blocked Air vents must not be...

Страница 10: ...e box with the wedge on the MF grate A facing up and forward Refit the Fuel retainer B remembering the lugs face towards the front of the stove and the cut out faces down Leave out the ash retainer th...

Страница 11: ...Description of product Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in c...

Страница 12: ...r 5 STDFDA5 STDFFOH STDFFOL Co 13 0 Wood 0 38 Ancit 0 40 5Kw 81 9 Wood 5Kw 70 7 Ancit 6931 1 Dartmoor W5 STDFDAW STDFHU co 13 0 Wood 0 38 Ancit 0 46 5Kw 80 6 Wood 5Kw 76 0 Ancit 60020 4 SE Dartmoor 6...

Страница 13: ...evant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee...

Страница 14: ...14...

Страница 15: ...n Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date of In...

Отзывы: