6
Fitting Instructions for the Baker 8
Stove
These fitting and operating instructions cover the Dartmoor 8 Stoves.
Introduction
The Dean Forge range of stoves has been continuously updated for over 37 years. These stoves have a
robust fully welded carcass with a cast iron door. This stove has sacrificial insulated bricks and steel
baffle plate and incorporates an air wash system with 3 outlet options- Top, Rear or Vertical Back box
outlets of 150mm (6”).
Unpacking Stove
Check all the fire bricks and baffle plate are in place and have not moved or been damaged in transit.
Inside the stove packed with these instructions will be gauntlet and a universal air vent- ash pan tool.
Before lighting the stove you must check that the installation has been carried out as per instructions
and complies with current building regulations.
Health and Safety Precautions
All work must be carried out to the required Health and Safety at Work Act 1974.
There must not be an extractor fan fitted in the room.
There must be an air vent for all stoves of 5 kilowatts and over or meet current building regulations.
Stoves must be fitted to BS8303, BS6461 PT1-2 1984 building regulations.
All local regulations, including those referring to national and European standards need to be complied
with when installing the appliance.
Flue Connections and Outlets
Baker 8 stoves have the option of taking the flue from the top or the back or using a vertical back box.
Horizontal flue from back of stove should not exceed 150mm.
All flue connections must be sealed with fire cement. Doors in the register plate must be present or a
soot box fitted in the back or side of the fireplace to enable access to clean the chimney when the stove
is installed without a liner.
If the chimney has been lined and cannot be swept through the stove an access door on the first length
of flue must be installed for cleaning access.
The Baker 8 model requires a 150mm (6”) first length of flue then a minimum of 150mm (6”) liner.
The installation of a flue liner is recommended.
N.B
All stoves must but installed by a suitably qualified person, such as a HETAS engineer or with the
supervision of building control.
As with all stoves fireguards must be installed when young children are present.
Содержание Dartmoor Baker 8