background image

 

 
 
 
 
 
 
Down draughts 
 
In adverse weather conditions a down draught may occur and will make the stove smoke, if this should 
happen shut all the stove air controls. 
If this occurs on a regular basis call in your engineer. 
It is possible a chimney cowl could cure this problem. 
 
 
 
R

efuelling  

 
When refuelling, the primary air control should be opened for a couple of minutes so that flames are 
established on the newly fuelled logs. The primary air should be closed once these flames are fully 
established and the logs have become blackened. 
After refuelling, do not leave the appliance unattended until it is certain that the logs are burning well 
with a sustained flame. 

 
Do not load the fuel above the log retainer. 

 

 
Fault finding 

 
If the stove starts emitting fumes into the room:-   
(1) Check there is no blockage or restriction in the flue. 
(2) Check the external air vent is not blocked. 
(3) Check the baffle plate has not dislodged itself from the stove. 
(4) Call an engineer. 
 
If the stove does not perform properly this could be due to unseasoned wood or too much ash in the 
firebox. 
In the case of the stove malfunctioning shut all vents, open the windows and let the residual fuel in 
stove burn out. 

 
 
In the event of a chimney fire 

 

 

Call the fire brigade 

 

Raise the alarm to let others in the house know 

 

Close down all the air controls of the stove, but be careful they could be very hot 

 

Move furniture, rugs and other objects away from the stove 

 

Check the chimney breast in other rooms for signs of excessive heat and move objects away if 
necessary 

 

At all times consider the safety of yourself and others in taking the above action 

 
  
 
 
 
 

Содержание Dartmoor Baker 8

Страница 1: ...ractor fan in the same room or space as the appliance the extractor fan could cause the stove not to function properly and pull dangerous fumes into the room This must be checked by a trained qualifie...

Страница 2: ...y two thirds the way down Dampers Left Open Operation with the air controls or appliance dampers open can cause excess smoke The appliance must not be operated with the air controls appliance dampers...

Страница 3: ...an ash clean attachment which can be plugged into your vacuum cleaner Please note If there is insufficient burning material in the fire bed to light a new fuel charge excessive smoke emission can occ...

Страница 4: ...w unwanted cooking smells out of the oven and into the chimney Do not block this vent off The top plate can be used as a cooking surface with the hottest area being near the back Please note if you do...

Страница 5: ...ult finding If the stove starts emitting fumes into the room 1 Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislo...

Страница 6: ...or all stoves of 5 kilowatts and over or meet current building regulations Stoves must be fitted to BS8303 BS6461 PT1 2 1984 building regulations All local regulations including those referring to nat...

Страница 7: ...oved to facilitate cleaning through the stove Hearth Surround and Register Plate The stove must stand on non flammable material at least 12mm thick 1 2 The hearth must extend at least 225mm in front o...

Страница 8: ...15 C Dean Forge Dartmoor Baker 8 Solid Fuel Ancit 320 C Flue Gas Mass Flow Stove Types Flue gas mass flow gs Dean Forge Dartmoor Baker 8 Wood Burning 7 2 Dean Forge Dartmoor Baker 8 Solid Fuel Ancit 7...

Страница 9: ...taken into account Please Note Extractor fans when operating in the same room or space as the appliance may cause problems Air vent inlet grills must not be inadvertently blocked Air vents must not be...

Страница 10: ...e box with the wedge on the MF grate A facing up and forward Refit the Fuel retainer B remembering the lugs face towards the front of the stove and the cut out faces down Leave out the ash retainer th...

Страница 11: ...Description of product Dartmoor wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Supplied in various sizes to give a range of heat output options Are in c...

Страница 12: ...r 5 STDFDA5 STDFFOH STDFFOL Co 13 0 Wood 0 38 Ancit 0 40 5Kw 81 9 Wood 5Kw 70 7 Ancit 6931 1 Dartmoor W5 STDFDAW STDFHU co 13 0 Wood 0 38 Ancit 0 46 5Kw 80 6 Wood 5Kw 76 0 Ancit 60020 4 SE Dartmoor 6...

Страница 13: ...evant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims under this guarantee...

Страница 14: ...14...

Страница 15: ...n Prior Buckfastleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number Date of Purchase Date of In...

Отзывы: