S P A Z I O
Operating instructions and warnings
14
now position the door/gate in its position of max. opening. In
order to do this:
•• Setup and memorization of motor stroke
WARNING During motors stroke memorisation, the control
board detects automatically the presence and type of photo-
cells, safety devices and limit switches which are installed. It is
therefore essential that during this phase the latter be properly
connected and working.
Instruct.
Function
Display
Manually position the door in the half open position
then power up the control panel, the panel is now
waiting for instructions.
Scroll down the parameters until you visualize pro-
cedure P003
Confirm! The control board awaits a further
confirmation
Confermare tenendo premuto il tasto OK! until
APPR stops flashing: control panel is ready to be
programmed.
Give a START impulse (by an already memorised
remote or a keypad): door opens.
Once it arrives at desired opening point, give a
START inpulse: door stops. Adjust the green cam so
that it presses the opening limit switch.
Give a START impulse: door closes.
Once it arrives at the closed position, door stops.
Adjust the red cam so that it presses the closing li-
mit switches. Display will show “----“, programming
complete.
•• Built-in radio receiver
DEA control board includes a 433,92MHz built-in radio receiver
accepting both transmitters with HCS coding (complete rolling
code or just fixed part), and HT12E dip-switch coding.
•The type of coding is selected by programming the working
parameter n° 8 “type of coding” (see Table 2 Parameters)
•The receiver memory capacity can contain up to 100 different
transmitters.
•When receiving a pulse from the transmitter, depending on
your channel selection and linking, the start or the pedestrian/
close inputs are activated. In fact, by programming one of the
working parameters it is possible to choose, according to one’s
needs, which key of the memorized transmitters will activate
the start input and which one will activate the pedestrian input
(see “Channel selection and linking on the transmitter”).
•While you memorize each transmitter the display shows a pro-
gressive number by which you will be able to trace and, if
necessary, delete each transmitter individually
Instruct.
Function
Display
The control board is ready to receive instructions
Deletion of all transmitters
Scroll down the parameters until you visualize
P004
Confirm! The control board awaits a further
confirmation
Confirm by pressing on the OK key for a few secon-
ds! The procedure starts
Done! The transmitters memory has been deleted
Scroll down the parameters until you visualize “----
”. The control board awaits further instructions
Memorization of transmitters
1
Scroll down the parameters until you visualize P005
Confirm! The receiver enters in memoriza-
tion mode. The flashing light turns on
Press on any key of the transmitter.
Memorization done! The flashing light
goes out for 2 seconds. The display vi-
sualizes the number of the transmitter just
memorized (es. “r001”)
The receiver reverts automatically to memori-
zation mode. The flashing light turns on again
Memorize all necessary transmitters
Wait 10 seconds before quitting the memo-
rization mode
The receiver will now receive all the memo-
rized transmitters
How to activate the memorization mode without
Operating on the control board
1
Press simultaneously on key CH1 and CH2,
or on the hidden key of a transmitter alrea-
dy memorized
How to search and delete a transmitter
Scroll down the parameters until you visualize
P006
Confirm! You can now select the transmitter
Scroll down the transmitter numbers until
you reach the transmitter to be deleted (eg.
“r003”)
Confirm the deletion by pressing the OK key for a
few seconds
OK! The transmitter is deleted
You can now select the parameter
Scroll down the parameters until you visua-
lize “----”. The control board awaits further
instructions
1
Make sure that the receiver is set to receive the type of coding of the tran-
smitter you wish to memorize: visualize and, if necessary, update parameter
n° 8 “type of coding” (see “Personalization of working parameters “)
•• Channel selection and linking on the transmitter
The built-in receiver can control both the start input and the
pedestrian/close one. By setting the correct value of the para-
meter “P009 Selection and linking of channels” it is possible to
decide which key of the transmitter will activate each input.
If you check on the “working parameters” table you will realize
that the P009 parameter allows you to choose among 16 dif-
ferent combinations. If, for instance, you attribute value “3” to
the parameter P009, all memorized transmitters will activate the
start input through the CH1 and the pedestrian input through
CH4. Please refer to chapter “Personalization of working para-
meters” in order to select your own combination..
•• Personalization of working parameters
Instruct.
Function
Display
The control board is ready to receive instructions
Scroll down the parameters until you visualize the
one you wish to set (ex. P010)
Confirm! The display shows the set parameter
value
Increase or decrease the value until you reach the
value you wish to define
Confirm! The display shows again the parameter
Scroll down the parameters until you visualise “----
”. The control board awaits further instructions
The automation is now ready to work according to the new working
parameters.
•• Resetting of default parameters (p.007)
DEA control board software includes a reset procedure to re-
store default values (the one set by the maker) of all settable pa-
rameters. The value originally set for each parameter is shown
in the “working parameters table”. In case you should reset all
Содержание Spazio 702 S