![Dea LIVI 3/24 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/dea/livi-3-24/livi-3-24_operating-instructions-and-warnings_2461003031.webp)
29
7 Transmitters learning
7.1 Transmitters coding selection
1.
Scroll down the parameters with
and keys until you visualise
P027;
2. Confirm by pressing on the
key;
3. Select the type of transmitter by scrolling and keys:
-
d000=fix rolling-code (
suggested
);
- d001=complete rolling-code;
-
d002=dip-switch;
4. Confirm by pressing on the key (display shows again P027).
Warning:
If you need to vary the type of encoding, and only if other remo-
tes with different encoding are memorized, you need to erase memory
(P004)
AFTER
you have set the new encoding.
7.2 Learning
1.
Scroll down the parameters with
and
keys until you visualise P005;
2. Confirm by pressing on the
key;
3. When the symbol “
” appears, press on
any key of the transmitter you want to memo
-
rize;
4. The display visualizes the number of the trans-
mitter just memorized and then “
”;
5. Memorize all necessary transmitters repeat-
ing this procedure from step 3;
6. Wait 10 seconds before quitting the memori
-
zation mode, display shows now “
- - - - “.
Warning:
In the case of rolling code remotes,
the receiver can be put into learning mode by
pressing the hidden button on a remote control
previously learned.
Warning:
When using personalized transmitters,
after entering P005 the learning of the first
personalized transmitter is possible only by
pressing its hidden button. Afterwards, only
transmitters personalized with the same
encryption key can be memorized (through the
usual procedure), unless a memory reset is
carried out (P004).
8 Adjustment of operating parameters
If you need to modify the operating parameters (force, speedness
etc..):
1. Scroll down the parameters until you visualize the desire pa
ram-
eter (i.g. P032);
2. Confirm by pressing on the
key;
3. By pressing on and , set up the desired value;
4. Confirm by pressing on the key (display shows the parameters
previously selected).
For the complete list of the “Operating Parameters” See the table
on page. 37.
9 Programming complete
WARNING
At the end of the programming procedure, use the buttons and until the appearance of the symbol “- - - - ”, the operator
is now ready again for new manoeuvres
.
To perform any “Advanced Programming” operations (cancellation of the remotes, configuration inputs, etc. ..), see on page 30.
Содержание LIVI 3/24
Страница 2: ......
Страница 22: ...20 ...
Страница 42: ...40 ...
Страница 62: ...60 ...
Страница 82: ...80 ...
Страница 102: ...100 ...
Страница 122: ...120 ...
Страница 142: ...140 ...
Страница 162: ...160 ...
Страница 164: ...162 240 320 188 82 70 200 450 350 125 70 27 5 23 5 288 62 5 58 Ø35 50 235 50 38 min 48 max ...
Страница 166: ...164 1 2 m m ...
Страница 181: ......
Страница 182: ......
Страница 183: ......