2 0 2 R R
Operating instructions and warnings
21
Wait 10 seconds before quitting the memorization mode
The receiver will now receive all the memorized transmitters
How to activate the memorization mode without operating on the control board
1
Press simultaneously on key CH1 and CH2, or on the hidden key of a
transmitter already memorized
How to search and delete a transmitter
Scroll down the parameters until you visualize P006
Confirm! You can now select the transmitter
Scroll down the transmitter numbers until you reach the transmitter to be
deleted (eg. “r003”)
Confirm the deletion by pressing the OK key for a few seconds
OK! The transmitter is deleted
You can now select the parameter
Scroll down the parameters until you visualize “----”. The control board awaits
further instructions
1
Make sure that the receiver is set to receive the type of coding of the transmitter you wish to memorize: visualize and, if
necessary, update parameter n° 8 “type of coding” (see “8.4 Personalization of working parameters “
Channel selection and linking on the transmitter
The built-in receiver can control both the start input and the pedestrian one. By setting the correct value
of the parameter “P009 Selection and linking of radio channels” it is possible to decide which key of the
transmitter will activate each input. If you check on the “working parameters” table you will realize that
the P009 parameter allows you to choose among 16 different combinations. If, for instance, you attribute
value “3” to the parameter P009, all memorized transmitters will activate the start input through CH1 and
the pedestrian input through CH4. Please refer to chapter “8.4 Personalization of working parameters”
in order to select the right combination.
8.4
Personalization of working parameters
Instructions
Function
Display
The control board is ready to receive instructions
Scroll down the parameters until you visualize the one you wish to set (ex. P010)
Confirm! The display shows the set parameter value
Increase or decrease the value until you reach the value you wish to define
Confirm! The display shows again the parameter
Scroll down the parameters until you visualise “----”.The control board awaits
further instructions
The automation is now ready to work according to the new working parameters.
8.5
Resetting of default parameters (p.007)
DEA 202RR control board software includes a reset procedure to restore default values (the one
set by the maker) of all settable parameters, see Table 2 Parameters. The value originally set for each
parameter is shown in the “working parameters table”. In case you should reset all values and restore
all default values, proceed as follows:
WARNING In case of an operator without encoder, each time you change the default parameters you
must repeat the operators run learning. If you do not do this, at first input the control panel doesn’t execute
any manoeuvre and the display shows for a few second “APPr” to remind you to repeat the learning.