Overview of authorizations
Start
-
up of the lock
Noodsleutel
Overview of the possible signals
Activating master
Event
When
Signal
Pressing the key
With every key stroke
1 x buzzer
Code valid
2 x Led green &
Correct input
After pressing Enter
2 x buzzer
Error message
After pressing Enter
3 x Led red &
Recurring input not matching
3 x buzzer
Cancelation (manual cancelation with or
time
-
controlled cancelation if there is no input)
Take
-
off contact
1 x Led red and
has been activated
3 x after pressing Enter
1 x , buzzer then
1 x Led green
and 1 x buzzer
Guard time
Permanently after
1 x Led red
pressing Enter
then 0.5 s break
Double code;
Permanently after
1 x Led green
input of the second
pressing Enter
then 2 s break
code is expected
OD
Permanently after
1 x Led red
pressing Enter
then 5 s break
OST
Permanently after
1 x Led green
pressing Enter
and buzzer then
5 s break
Undervoltage
After pressing Enter
10 x Led red
Programming mode
Permanently after
1 x buzzer and
pressing Enter
constinuous
signal LED green
Remote disable
with every key stroke
1 x Led red
activated, no
opening possible
Hardware error.
Contact the Service.
3 x buzzer and
After pressing Enter
continuous red
Code status messages
Code active
After pressing Enter
1 x Led green
and a buzzer
Description
1. Press
“
P
”
and arrow, Enter the new master code (00 xxxxxx)
and enter the arrow. (
00 = ID, X = freely selected 6
-
digit
combination [0..9])
Confirm the new master code with (00 xxxxxx) and press the
arrow.
Then check the performed programming with the storage unit
still open. To do so, proceed according to chapter 10.1.
NOTE
: If the Incorrect code signal is output, the procedure must
be repeated since both codes do not match or the ID (here 00)
has been entered incorrectly. Changing of the master code can
be canceled any time by pressing twice. Alternatively, the
process can be canceled if no input is performed within 30
seconds.
Overview of the programming commands
The lock installation as well as cabling and the first battery instal-
lation are described in the installation manual. As long as the lock
system has not been put into operation, it can be opened using
the assembler code. The assembler code is intended for lock
mounting at the factory and not for further permanent use. For
correct start
-
up of the lock the master code must be activated
correctly according to chapter 8.2, this makes the assembler code
invalid.
NOTE
: If the start
-
up or partial start
-
up has already been perfor-
med by the safe manufacturer or distributor, the corresponding
information is specified in its manuals/notes. Furthermore, the
safe manufacturer or distributor can document the set master
code in this manual. For this information refer to the field high-
lighted in gray in chapter 1 page 28, "Master code set by the dis-
tributor resp. safe manufacturer".
Opening with assembler code
1. Press 1 and the arrow you will see/hear 2x green led and 2x a
buzzer if it is correct. If not you will see 3x red Led and 3x a buz-
zer.
2. Turn the actuating knob within 4 seconds through 90° clock-
wise to the stop . Then open the storage unit.