Overview of authorizations 

 

 

Start

-

up of the lock 

 

 

 

 

 

 

Noodsleutel

 

 

Overview of the possible signals 

 

 

Activating master 

 

Event

   

 

 

When

   

 

Signal

 

Pressing the key 

 

With every key stroke 

 

1 x buzzer

 

 

Code valid

 

 

 

 

 

 

2 x Led green &

 

Correct input 

  

After pressing Enter 

  

2 x buzzer 

 

Error message 

 

After pressing Enter 

  

3 x Led red  &

 

Recurring input not matching 

 

 

 

3 x buzzer

 

Cancelation (manual cancelation with or 

 

time

-

controlled cancelation if there is no input)  

 

Take

-

off contact 

 

 

 

 

 

1 x Led red and 

 

has been activated 

 

3 x after pressing Enter 

 

1 x , buzzer then 

 

 

 

 

 

 

 

1 x Led green 

 

 

 

 

 

 

 

 

and 1 x buzzer

 

Guard time 

   

Permanently after 

   

1 x Led red

 

 

 

 

pressing Enter

 

 

then 0.5 s break

 

Double code; 

  

Permanently after 

   

1 x Led green

 

input of the second 

 

pressing Enter

 

 

then 2 s break 

 

code is expected 

 

OD 

 

 

 

Permanently after 

   

1 x Led red  

 

 

 

 

pressing Enter 

 

 

then 5 s break 

 

OST 

   

 

Permanently after 

   

1 x Led green 

 

 

 

 

pressing Enter 

 

 

and buzzer then 

 

 

 

 

 

 

 

5 s break

 

Undervoltage 

 

After pressing Enter 

  

10 x Led red 

 

Programming mode 

 

Permanently after 

   

1 x buzzer and

 

 

 

 

pressing Enter 

 

 

constinuous

 

 

 

 

 

 

 

 

signal LED green

 

Remote disable 

 

with every key stroke

 

1 x Led red

 

activated, no 

 

opening possible 

 

Hardware error. 

 

Contact the Service. 

  

3 x buzzer and 

 

 

 

 

After pressing Enter 

  

continuous red

 

Code status messages 

 

Code active 

   

After pressing Enter 

  

1 x Led green 

 

 

 

 

 

 

 

 

and a buzzer

 

Description 

 

1. Press 

P

” 

and arrow, Enter the new master code (00 xxxxxx) 

and enter the arrow. (

00 = ID, X = freely selected 6

-

digit 

combination [0..9]) 

 

Confirm the new master code with (00 xxxxxx) and press the 
arrow. 

 

Then check the performed programming with the storage unit 
still open. To do so, proceed according to chapter 10.1.

 

NOTE

: If the Incorrect code signal is output, the procedure must 

be repeated since both codes do not match or the ID (here 00) 
has been entered incorrectly. Changing of the master code can 
be canceled any time by pressing twice. Alternatively, the 
process can be canceled if no input is performed within 30 
seconds. 

 

 

Overview of the programming commands 

 

The lock installation as well as cabling and the first battery instal-
lation are described in the installation manual. As long as the lock 
system has not been put into operation, it can be opened using 
the assembler code. The assembler code is intended for lock 
mounting at the factory and not for further permanent use. For 
correct start

-

up of the lock the master code must be activated 

correctly according to chapter 8.2, this makes the assembler code 
invalid. 

 

NOTE

: If the start

-

up or partial start

-

up has already been perfor-

med by the safe manufacturer or distributor, the corresponding 
information is specified in its manuals/notes. Furthermore, the 
safe manufacturer or distributor can document the set master 
code in this manual. For this information refer to the field high-
lighted in gray in chapter 1 page 28, "Master code set by the dis-
tributor resp. safe manufacturer". 

 

 

Opening with assembler code 

 

1. Press 1 and the arrow you will see/hear 2x green led and 2x a 
buzzer if it is correct. If not you will see 3x red Led and 3x a buz-
zer.

 

 2. Turn the actuating knob within 4 seconds through 90° clock-
wise to the stop . Then open the storage unit. 

 

Содержание Code combi B 30

Страница 1: ...ctions of the lock and loose the right for the warranty claims During start up the serial number of the input unit is saved in the audit memory of the lock Replacement of the input unit is also registered by means of an entry in the audit memory of the lock For every description of operation or programming processes hereafter it is assumed that the lock and the input unit are in the basic state Ba...

Страница 2: ... intruder EMA Intruder detection system external alarm system for evaluation forwarding of the duress alarm or secured permanent power supply not included in the scope of delivery Undervoltage indication indicates that the batteries are low and must be replaced as soon as possible in order to ensure secure function of the lock AHK Take off contact A contact in the input unit which detects whether ...

Страница 3: ...th 00 xxxxxx and press the arrow Then check the performed programming with the storage unit still open To do so proceed according to chapter 10 1 NOTE If the Incorrect code signal is output the procedure must be repeated since both codes do not match or the ID here 00 has been entered incorrectly Changing of the master code can be canceled any time by pressing twice Alternatively the process can b...

Страница 4: ...ribes the basic programming procedures for further codes user or courier codes This includes activation deletion blocking and releasing of these codes The basic code structure is given in chapter 5 authorizations Furthermore this chapter describes the code status query used by the master co de to request the status of individual codes directly from the lock For correct use of the lock the master c...

Страница 5: ...hat the silent alarm is activated and the alarm codes can be used Description 1 Press P and enter the valid master code and arrow Press P8 and arrow NOTE The silent alarm must be deactivated in order to be able to activate it If the red LED is displayed additionally to the normal acknowledgment signal the silent alarm has been activated previ ously and is deactivated now To activate it again repea...

Страница 6: ...ion key The OD can be avoided if the inspec tion key is used but it cannot be deleted Opening with silent alarm Description 1 Enter the first valid opening code and arrow ID 00 to 30 or 95 X programmed 6 digit combination for the corresp ID num ber 2 Now the signal for the input of the second is displayed 1x Led green 2 s break 3 Enter another valid opening code and arrow ID 00 to 30 or 95 however...

Страница 7: ...tandby times have been programmed they can be overridden here c Double code override This function turns the programmed double code into a simple code The second code which is requi red usually is omitted here d Omission alarm If this function is activated at the lock an se parate input signal must be initiated max 60 seconds before the code input e g by means of a hidden button otherwise the lock...

Страница 8: ...ly recommended to use high quality brand batteries and replace them as a precauti on every 24 months at the latest After the battery replacement mount the input unit on the base part from the front in the or der reverse to the one described above and move it laterally until it engages and the red LED turns off Then attach the screw to secure the top part Now attach the rotary handle in the posi ti...