Opening the lock without programmed OD/OST 

 

 

Opening with double code 

 

 

 

 

Lock functions for all users 

 

Every key stroke is confirmed by a key tone ( ). The input can be 
canceled any time by pressing 

P

” 

twice. Alternatively, the input 

can be canceled if no input is performed within 10 seconds. 
After three incorrect code inputs the lock switches to guard ti-
me. For details on the guard time refer to chapter 10.5. If the 
undervoltage signal (10x LED green ) is displayed after the code 
entry, then the battery capacity is low and the batteries must be 
replaced as soon as possible. If the take

-

off contact signal (3x 

LED green and 3x LED red alter 6x buzzer) is displayed 
after the code entry, the input unit has been opened. The lock 
has a function which hinders spying out of codes by means of 
user observation during code input: During all opening procedu-
res the operator can add as many further digits as necessary 
before completing the input by pressing . All inputs starting from 
the 9th position will be ignored. Notice: This function supports 
only the code input for opening and is not available for the pro-
gramming procedures. Opening with activated additional func-
tions: The lock offers an option to execute further additional 
functions triggered by external signals.  

 

Description 

 

1. Enter a valid opening code and arrow (ID = 00 to 30 resp. 95, 
X = programmed 6

-

digit combination for the corresp. ID num-

ber). 

 

Turn the actuating knob within 4 seconds through 90° clockwise 
to the stop 

 

Opening the lock with programmed OD/OST 

 

Description 

 

1. Enter a valid opening code and  arrow (ID = 00 to 30 or 95, X = 
programmed 6

-

digit combination for the corresp. ID number) If 

you have entered a courier code here, proceed directly with 
step .

 

2. If you have not entered any courier code (ID 95), the signal for 
the running opening delay is displayed now (1x LED red ; 5 s 
break). Wait until it is completely over. 

 

3. The opening standby time starts after the opening delay (1x 
LED green, Now enter a valid opening code and arrow again (ID 
= 00 to 30, X = programmed 6

-

digit combination for the corresp. 

ID number).

 

4. Turn the actuating knob within 4 seconds through 90° clockwi-
se to the stop 

 

The running opening delay can be canceled any time by pressing 

P

” 

twice. If the Incorrect code signal is output after the code 

input, the entry must be repeated completely. After 3 incorrect 
inputs the lock switches to the guard time. Courier code: After 
entering the courier code (ID 95) the lock can be opened imme-
diately if the programmed OD (opening delay) is avoided in a 
certain manner (steps 2 and 3 are omitted). Double code mode: 
In the double code mode the entire double code must be ente-
red. The OD is, thus, started only by the input of an individual 
code. Avoiding the OD/OST with the courier code in the double 
code mode: To enable this, the courier code must be the first 
entered code in the double code mode. Then the second code 
(not the courier code) can be entered and after that the lock can 
be opened. Inspection key: The OD can be avoided if the inspec-
tion key is used, but it cannot be deleted 

 

 

Opening with silent alarm 

 

Description 

 

1. Enter the first valid opening code and arrow (ID = 00 to 30 or 
95, X = programmed 6

-

digit combination for the corresp. ID num-

ber) 

 

2. Now the signal for the input of the second is displayed (1x Led 
green ; 2 s break) 

 

3. Enter another valid opening code and arrow (ID = 00 to 30 or 
95, however, other than in step 1, Y = programmed 6

-

digit com-

bination for the corr. ID number) 

 

4. Turn the actuating knob within 4 seconds through 90° clockwi-
se to the stop 

 

NOTE

: The operator IDs of both codes must not match. The or-

der of the code input is irrelevant, unless it is necessary to open 
the lock while avoiding the OD/OST, then refer to 10.2. If the 
Incorrect code signal is output after the first code input, the en-
try must be repeated completely. If the Incorrect code signal is 
displayed after the second code input, the second entered code 
is incorrect or identical to the first input (identical IDs). In both 
cases the input must be repeated completely. After a total of 3 
incorrect inputs the lock switches to the guard time (see chapter 
10.5). It is irrelevant here, whether the faulty input was in the 
first or the second code. Even if the faulty inputs occur in the 
first or second code alternately, after 3 incorrect inputs the lock 
switches to the guard time. 

 

If there is a threatening situation, the lock can be opened with 
simultaneous generation of a silent alarm, provided the silent 
alarm has been activated and the lock is connected to an intruder 
detection system (not included in the scope of delivery). A special 
alarm code derived from a valid code must be entered for this 
purpose (if the double code is activated, one of the codes is suffi-
cient). If an alarm code is entered, the lock opens externally as 
usual but a silent alarm is initiated additionally without further 
visible/audible feedback. The alarm code consists of a valid code, 
the last position/digit of this code is increased or decreased by 
one digit (+1 or 

-

1). If the last code digit is 0 or 9, then the digit 

next to the last in the alarm code is not changed. If an opening 
delay has been programmed, this time has to elapse still in spite 
of the alarm code input. If the silent alarm is deactivated, the 
alarm codes are acknowledged as incorrect codes and the lock 
cannot be opened resp. the OD is not activated. 

 

Description

 

1. Enter a modified valid opening code as an alarm code and ar-
row (ID = 00 to 30 or 95, X = the first 5 positions of the program-
med 6

-

digit combination for the corr. ID number, Y = increased by 

1 or decreased at the 6th position of the combination mentioned 
above) 

 

2. Turn the actuating knob within 4 seconds through 90° clockwi-
se to the stop . 

 

If the Incorrect code signal is output after the code input, the 
entry must be repeated completely. After 3 incorrect inputs the 
lock switches to guard time in this case as well (see chapter 10.5) 
Double code: With the activated double code it is sufficient to 
enter both codes as alarm codes in order to activate the silent 
alarm. However, the alarm is activated only if both codes requi-
red for opening have been entered completely. 

 

Содержание Code combi B 30

Страница 1: ...ctions of the lock and loose the right for the warranty claims During start up the serial number of the input unit is saved in the audit memory of the lock Replacement of the input unit is also registered by means of an entry in the audit memory of the lock For every description of operation or programming processes hereafter it is assumed that the lock and the input unit are in the basic state Ba...

Страница 2: ... intruder EMA Intruder detection system external alarm system for evaluation forwarding of the duress alarm or secured permanent power supply not included in the scope of delivery Undervoltage indication indicates that the batteries are low and must be replaced as soon as possible in order to ensure secure function of the lock AHK Take off contact A contact in the input unit which detects whether ...

Страница 3: ...th 00 xxxxxx and press the arrow Then check the performed programming with the storage unit still open To do so proceed according to chapter 10 1 NOTE If the Incorrect code signal is output the procedure must be repeated since both codes do not match or the ID here 00 has been entered incorrectly Changing of the master code can be canceled any time by pressing twice Alternatively the process can b...

Страница 4: ...ribes the basic programming procedures for further codes user or courier codes This includes activation deletion blocking and releasing of these codes The basic code structure is given in chapter 5 authorizations Furthermore this chapter describes the code status query used by the master co de to request the status of individual codes directly from the lock For correct use of the lock the master c...

Страница 5: ...hat the silent alarm is activated and the alarm codes can be used Description 1 Press P and enter the valid master code and arrow Press P8 and arrow NOTE The silent alarm must be deactivated in order to be able to activate it If the red LED is displayed additionally to the normal acknowledgment signal the silent alarm has been activated previ ously and is deactivated now To activate it again repea...

Страница 6: ...ion key The OD can be avoided if the inspec tion key is used but it cannot be deleted Opening with silent alarm Description 1 Enter the first valid opening code and arrow ID 00 to 30 or 95 X programmed 6 digit combination for the corresp ID num ber 2 Now the signal for the input of the second is displayed 1x Led green 2 s break 3 Enter another valid opening code and arrow ID 00 to 30 or 95 however...

Страница 7: ...tandby times have been programmed they can be overridden here c Double code override This function turns the programmed double code into a simple code The second code which is requi red usually is omitted here d Omission alarm If this function is activated at the lock an se parate input signal must be initiated max 60 seconds before the code input e g by means of a hidden button otherwise the lock...

Страница 8: ...ly recommended to use high quality brand batteries and replace them as a precauti on every 24 months at the latest After the battery replacement mount the input unit on the base part from the front in the or der reverse to the one described above and move it laterally until it engages and the red LED turns off Then attach the screw to secure the top part Now attach the rotary handle in the posi ti...

Отзывы:

Похожие инструкции для Code combi B 30