Opening the lock without programmed OD/OST
Opening with double code
Lock functions for all users
Every key stroke is confirmed by a key tone ( ). The input can be
canceled any time by pressing
“
P
”
twice. Alternatively, the input
can be canceled if no input is performed within 10 seconds.
After three incorrect code inputs the lock switches to guard ti-
me. For details on the guard time refer to chapter 10.5. If the
undervoltage signal (10x LED green ) is displayed after the code
entry, then the battery capacity is low and the batteries must be
replaced as soon as possible. If the take
-
off contact signal (3x
LED green and 3x LED red alter 6x buzzer) is displayed
after the code entry, the input unit has been opened. The lock
has a function which hinders spying out of codes by means of
user observation during code input: During all opening procedu-
res the operator can add as many further digits as necessary
before completing the input by pressing . All inputs starting from
the 9th position will be ignored. Notice: This function supports
only the code input for opening and is not available for the pro-
gramming procedures. Opening with activated additional func-
tions: The lock offers an option to execute further additional
functions triggered by external signals.
Description
1. Enter a valid opening code and arrow (ID = 00 to 30 resp. 95,
X = programmed 6
-
digit combination for the corresp. ID num-
ber).
Turn the actuating knob within 4 seconds through 90° clockwise
to the stop
Opening the lock with programmed OD/OST
Description
1. Enter a valid opening code and arrow (ID = 00 to 30 or 95, X =
programmed 6
-
digit combination for the corresp. ID number) If
you have entered a courier code here, proceed directly with
step .
2. If you have not entered any courier code (ID 95), the signal for
the running opening delay is displayed now (1x LED red ; 5 s
break). Wait until it is completely over.
3. The opening standby time starts after the opening delay (1x
LED green, Now enter a valid opening code and arrow again (ID
= 00 to 30, X = programmed 6
-
digit combination for the corresp.
ID number).
4. Turn the actuating knob within 4 seconds through 90° clockwi-
se to the stop
The running opening delay can be canceled any time by pressing
“
P
”
twice. If the Incorrect code signal is output after the code
input, the entry must be repeated completely. After 3 incorrect
inputs the lock switches to the guard time. Courier code: After
entering the courier code (ID 95) the lock can be opened imme-
diately if the programmed OD (opening delay) is avoided in a
certain manner (steps 2 and 3 are omitted). Double code mode:
In the double code mode the entire double code must be ente-
red. The OD is, thus, started only by the input of an individual
code. Avoiding the OD/OST with the courier code in the double
code mode: To enable this, the courier code must be the first
entered code in the double code mode. Then the second code
(not the courier code) can be entered and after that the lock can
be opened. Inspection key: The OD can be avoided if the inspec-
tion key is used, but it cannot be deleted
Opening with silent alarm
Description
1. Enter the first valid opening code and arrow (ID = 00 to 30 or
95, X = programmed 6
-
digit combination for the corresp. ID num-
ber)
2. Now the signal for the input of the second is displayed (1x Led
green ; 2 s break)
3. Enter another valid opening code and arrow (ID = 00 to 30 or
95, however, other than in step 1, Y = programmed 6
-
digit com-
bination for the corr. ID number)
4. Turn the actuating knob within 4 seconds through 90° clockwi-
se to the stop
NOTE
: The operator IDs of both codes must not match. The or-
der of the code input is irrelevant, unless it is necessary to open
the lock while avoiding the OD/OST, then refer to 10.2. If the
Incorrect code signal is output after the first code input, the en-
try must be repeated completely. If the Incorrect code signal is
displayed after the second code input, the second entered code
is incorrect or identical to the first input (identical IDs). In both
cases the input must be repeated completely. After a total of 3
incorrect inputs the lock switches to the guard time (see chapter
10.5). It is irrelevant here, whether the faulty input was in the
first or the second code. Even if the faulty inputs occur in the
first or second code alternately, after 3 incorrect inputs the lock
switches to the guard time.
If there is a threatening situation, the lock can be opened with
simultaneous generation of a silent alarm, provided the silent
alarm has been activated and the lock is connected to an intruder
detection system (not included in the scope of delivery). A special
alarm code derived from a valid code must be entered for this
purpose (if the double code is activated, one of the codes is suffi-
cient). If an alarm code is entered, the lock opens externally as
usual but a silent alarm is initiated additionally without further
visible/audible feedback. The alarm code consists of a valid code,
the last position/digit of this code is increased or decreased by
one digit (+1 or
-
1). If the last code digit is 0 or 9, then the digit
next to the last in the alarm code is not changed. If an opening
delay has been programmed, this time has to elapse still in spite
of the alarm code input. If the silent alarm is deactivated, the
alarm codes are acknowledged as incorrect codes and the lock
cannot be opened resp. the OD is not activated.
Description
1. Enter a modified valid opening code as an alarm code and ar-
row (ID = 00 to 30 or 95, X = the first 5 positions of the program-
med 6
-
digit combination for the corr. ID number, Y = increased by
1 or decreased at the 6th position of the combination mentioned
above)
2. Turn the actuating knob within 4 seconds through 90° clockwi-
se to the stop .
If the Incorrect code signal is output after the code input, the
entry must be repeated completely. After 3 incorrect inputs the
lock switches to guard time in this case as well (see chapter 10.5)
Double code: With the activated double code it is sufficient to
enter both codes as alarm codes in order to activate the silent
alarm. However, the alarm is activated only if both codes requi-
red for opening have been entered completely.