Troubleshooting Guide
Table 2 Fault Troubleshooting Guide
System Display
Fault/Behavior
Cause (most likely to
least likely)
Remedial Action
RUNNING
WAITING FOR
FLOW
Insufficient feed water
to the system.
1.
Sudden loss of
feed water to
the system.
2.
Low pressure
surge in feed
line due to main
pump
shutdown.
3.
Blockage of feed
line.
1.
Ensure feed water valve
is open and water is
reaching the OSG.
2.
Ensure feed water
supply meets system
specifications (25 psi
min, 75 psi max).
3.
Check all tubing and
piping for obstructions.
STANDBY TANK
DRAINING
Mixed-oxidant solution
is between high and
low level float set-
points.
1.
Mixed oxidant in
solution tank is
in the injection
phase (normal
operation).
2.
Low level float
malfunctioning.
1.
Wait for tank to reach
low level for OSG to
begin generation again.
2.
Verify low level float is
actuating/wired properly
(Figure 12 Oxidant Tank
Level Switch Wiring to
Control Box).
STANDBY TANK
FULL
Mixed-oxidant solution
has reached the top
level float.
1.
Oxidant tank is
full (normal
operation).
2.
High level float
malfunctioning.
1.
Wait for tank to reach
low level for OSG to
begin generation again.
2.
Verify High level float is
actuating/wired properly
(Figure 12).
HARD FAULT
TANK FLOAT
STUCK
Solution tank float
switches are sending
invalid signals. (e.g.
high sensor tripped
without low sensor
tripping).
1.
High level or
low level float
stuck in
position.
2.
Poor electrical
connections to
floats
1.
Verify floats are
actuating properly
2.
Double check electrical
connections to ensure
they are secure.
3.
Verify floats are wired
properly (Figure 12).
HARD FAULT BAD
CELL PS
Minimum power
supply voltage not
met.
1.
Bad 12 VDC
power supply
1.
Contact MIOX Customer
Support.