MIOX AE Series Operators Manual
102-00085-E
Page
24
Figure 10 Ventilation Requirements
Level Switch Installation
For MIOX-supplied oxidant storage tanks, the level switch is
shipped loose in the tank. If the oxidant storage tank is not
shipped with the AE™ Series OSG, the switch is shipped
separately. The switch is designed to operate with the AE™
Series OSG. To install the level switch in the tank, complete the
following steps (Figure 11):
1.
Wrap the male end of the street elbow with Teflon tape
and connect it inside the solution tank into the ½”
bulkhead adapter at the top of the tank.
2.
Feed the electrical cord through the elbow and out of
the tank.
3.
Seal the male end of the liquid level switch with Teflon
tape and screw it into the female end of the street elbow.
Hand tighten only.
(continued on next page)
Figure 11 Level Switch Installation