background image

     

 

 

11

 / 

14

 

 

WWW.DDTOP.COM 

6.3.3 Steplessly Adjustable 
The UQK-103 float level switch has a stepless adjustment range, see Figure 7. The movement limit is adjusted by 
changing the relative positions of the upper and lower limit screws of the float guide bar, and the adjustment 
range  is  0  to  1000  mm.  There  is  a  slidable  counterweight  on  the  balance  bar.  When  the  upper  limit  is  used, 
moving the counterweight makes the right side slightly lighter than the float side (excluding the float). When the 
lower limit is used, the counterweight side should be slightly heavier than the float side (Does not contain floats) 
weight. UQK-103 float level switch controller float diameter Ф140, larger than flange nominal diameter DN80, so 
its top cover must be removable. 

 

Figure 7 Stepless adjustable 

7. Debugging 

7.1 Preparation for commissioning 

7.1.1

 Debugging Tool: Multimeter   

7.2 Electrical Wiring 

7.2.1 Cable preparation: Wiring should be Ф10mm OD five-core rubber sleeve cord or rubber cable, one core is 
the inner grounding wire, and the other four cores are for a pair of normally open and normally closed contact 
wires (using two cores),or for two pairs of normally open, normally closed contacts. 

7.2.2 Electrical wiring 

1. Remove the cover. 

2.According to the wiring diagram wiring, please note that the over-reporting and under-reporting switches are 
opposite. Be sure to connect to the correct terminal according to the wiring diagram (see Figure 8). For the SPDT 

Содержание UQK-100

Страница 1: ...1 14 WWW DDTOP COM UQK S 100 FLOAT LEVEL SWITCH Operation Manual UQK S 100 DT JS 1017 2018 A...

Страница 2: ...ut prior notice Quality Assurance Dandong Top Electronics Instrument Group Co Ltd guarantees that all glass plate level gauge have no defects in materials and manufacturing processes within one year f...

Страница 3: ...5 Warehousing 6 3 Technical Characteristics 6 3 1 Main Performance 6 3 2 Main Parameters 6 4 Dimensional Schematic Figure 3 6 5 Unpacking and Inspection 8 5 1 Unpacking Inspection Notice 8 5 2 Check C...

Страница 4: ...e or non flammable site operating procedures 1 2 Process Leaks Can Cause Serious Injury or Death Care should be taken to lift the transmitter If the process seal is damaged the medium may leak at the...

Страница 5: ...is turned on or off so that the control signal alarm device alarms or starts and stops the electric pump During the lifting and lowering of the float only when the float is in the upper and lower lim...

Страница 6: ...on functional safety level SILII 3 2 Main Parameters 3 2 1 Voltage AC220V DC24V 3 2 2 Output Signal Relay Contact SPDT or DPDT 4 Dimensional Schematic Figure 3 If the order is required to be a special...

Страница 7: ...7 14 WWW DDTOP COM...

Страница 8: ...8 14 WWW DDTOP COM 5 Unpacking and Inspection 5 1 Unpacking Inspection Notice 5 1 1 Check whether the product nameplate Figure 4 is consistent with the supply list information...

Страница 9: ...flange bolts for process connections 6 1 2 Level 6 2 Installation Technical Requirements 6 2 1 Ensure that the lead length L and inner diameter of the equipment are suitable for the selected float lev...

Страница 10: ...the controller flange with the container flange to ensure that the controller wiring is facing downwards except for the top mounting method Rotate the controller flange to align the bolt holes Make su...

Страница 11: ...float level switch controller float diameter 140 larger than flange nominal diameter DN80 so its top cover must be removable Figure 7 Stepless adjustable 7 Debugging 7 1 Preparation for commissioning...

Страница 12: ...ing Process 7 3 1 Ordinary float level controller lift or lower the float to simulate level lift before installation and use a multimeter to verify whether the output status is correct Figure 8 output...

Страница 13: ...nomenon Cause of Issue Troubleshooting Method The level to the specified position switch does not work 1 The ball is too heavy not floating 2 The installation location is wrong 3 The lead pipe is too...

Страница 14: ...ssure inside the vessel high temperatures corrosive or toxic media etc Refer to the instructions in section 6 3 Installation Operation and Section 7 2 Electrical Wiring to remove the parts in the reve...