In addition each unit retains statistical and max data. Most of this information is visible via the PC interface. Some of 

this information is ‘attached’ to the CAL3K-A chassis, some of it is contained on the control card, and a different data 

set is in the vessel. 

If a vessel, chassis, or control card is replaced in the field then some of the product identification may be different 

from what our records reflect and we need your assistance to inform us accordingly. 

 

 

 

WARRANTY – FOR NEW PRODUCTS 

PURPOSE OF PRODUCT WARRANTY 

Any part of a product is subject to ageing and eventual failure. These failures occur during normal use.  The purpose 

of a warranty is to protect the Owner against a part failure caused by manufacturing defects in workmanship, 

material or design for a specific time.  

 

OWNER’S WARRANTY 

In the event of the Owner contracting directly with Digital Data Systems (Pty) Ltd “dds”, or in the event of the 

installation of a unit arising out of a contract between the Owner’s Dealer or any other party on his/her behalf and 

the said “dds”, the Owner records that not withstanding same, this warranty is the only warranty applicable to “dds” 

units and is expressly in lieu of all other warranties, expressed or implied, including any implied warranty of 

merchantability or fitness for a particular purpose. No amendments or additions to this warranty shall be binding on 

dds”, unless recorded in writing and signed by a duly authorised officer of the company.  “dds” agrees to repair and 

replace with a new or remanufactured part, any part, other than those excluded below, which after inspection, 

upon its return to the factory in Randburg, Johannesburg by the Owner or the authorised Dealer to which he/she 

returns the unit, is proven to be defective.  

 

Replacement of a defective part will be made only within the applicable warranty period of 12 (twelve) months from 

date of shipment. Not withstanding anything to the contrary herein, any labour involved in repairing or replacing a 

defective part will be charged at “dds” rates applicable at the time. 

 

If upon inspection it is found that the pressure vessel was submerged in water the warranty will automatically be 

null and void and the owner will be responsible for the labour and parts charges.  

 

EXCLUDED (NON-WARRANTY) PARTS 

dds” shall be entitled to treat this warranty as void unless the relevant warranty form (attached) is sent by 

registered post to “dds” by the Owner within 10 (ten) days from date of original installation.  

 

Regardless of warranty-status, the Owner shall be responsible for labour charges connected with periodic 

maintenance requirements involving visual and functional inspection of the systems.  

 

This warranty expressly covers the unit(s) “dds” supplied only and does not cover any other part, which may, as a 

consequence of the installation and operation of the unit, become damaged in any way whatsoever.  

 

Special attention should be given to the safe operation of the high-pressure Vessels. The published rules are 

guidelines only and enclosed in this leaflet for the convenience of the User. The manufacturer is not responsible 

Содержание CAL3K-A

Страница 1: ...cturers of CAL2K CAL3K Oxygen Bomb Calorimeters CAL3K A INSTALLATION GUIDE V1 1 www ddscalorimeters com calo ddsystems co za CAL3K A INSTALLATION GUIDE VERSION 1 1 MANUFACTURED BY DIGITAL DATA SYSTEMS...

Страница 2: ...A CALORIMETER WITH EXTERNAL oxygen filling 6 THE 3K 2 AIR COOLER 6 THE 3K 5 BAYONET VESSEL 7 THE CAL2K 3 OXYGEN FILLING STATION 7 7 UNPACKING AND INSPECTION 7 SETTING UP 8 PREREQUISITES 8 SITE SELECT...

Страница 3: ...INATE USER TEST 16 16 CAL3K A USER TEST 16 16 SUBJECT HELP 16 OTHER KEYBOARD COMMANDS 16 ABORT 16 FIRE MANUAL 16 CALIBRATION 16 READ RESULT 17 CONNECTING TO A BALANCE 17 17 CALIBRATION 18 INTELCAL CAL...

Страница 4: ...and the factory calibration But there is more Information and capability This is not explained here but in an ON LINE version It is safe to say that you need a PC or laptop to change from the basic o...

Страница 5: ...Bottle 2 3K A INST CAL3K A Installation Guide Printed 1 3K 2 CAL3K Air Cooler 1 3K 2 KT CAL3K Air Cooler Installation Kit 1 Included in Kit 3K SM Power Supply 1 KETTLECORD Mains Cable 220 V 1 CAL2K 3...

Страница 6: ...e calorimeter and the lid is closed The rest is automatic Width 270mm Height 200mm Depth 380mm Weight 8kg Power 220 240V 12W THE 3K 2 AIR COOLER The air cooler requires no water piping or other resour...

Страница 7: ...ight 150mm Weight 1 9kg THE CAL2K 3 OXYGEN FILLING STATION The oxygen filling station is connected to the oxygen bottle via a regulator The regulator reduces the bottle pressure to 30bar which is adju...

Страница 8: ...contact your agent SETTING UP PREREQUISITES Prior to installation of the CAL3K A System the User must provide the following 1 A mains outlet for the 3K 1_A Calorimeter and a mains outlet for the 3K 2...

Страница 9: ...HE FILLING PRESSURE IS ADJUSTABLE on the regulator the filling speed is adjustable on the filling station REMEMBER You may fill the Vessel LESS than 3000KPA but NEVER more than 3000KPA FILLING STATION...

Страница 10: ...to the outside or any suitable scrubber to prevent the burned gas to enter the room COOLER 3K 2 Electrical shock There are no user serviceable parts inside VESSEL 3K 5 The Vessel has been pressure tes...

Страница 11: ...DS CALORIMETERS www ddscalorimeters com Manufacturers of CAL2K CAL3K Oxygen Bomb Calorimeters CAL3K A INSTALLATION GUIDE V1 1 www ddscalorimeters com calo ddsystems co za CAL3K A REAR PANEL CONNECTION...

Страница 12: ...test is logged into the Event Logging and the User Test Log It is recommended to repeat the hardware once a day or once per shift The hardware test takes approximately 1 minute to complete NOTE While...

Страница 13: ...CAL3K A hardware test The unit cycles through the following steps and stops for operator action or when a fault is encountered Will stop the test The results of the test are logged together with the V...

Страница 14: ...password Function keys They serve as a shortcut to the keyboard commands The following function keys are used F1 Mass entry F1 Enter 0 xxxx Enter F2 Sample Identification F2 Enter mysampleId Enter F3...

Страница 15: ...6 character or shorter string SPIKE MASS Enter the weight of the spike mass here A spike mass of zero disables spiking For details of spiking see www ddscalorimeters com BALANCE MASS The supplied bala...

Страница 16: ...nit waits for an action a more detailed subject help is available to explain what is needed Press whenever something does not progress and read the comments OTHER KEYBOARD COMMANDS Here are some handy...

Страница 17: ...e stable balance weight should show on the display If you press Enter then the mass is locked See MASS ENTRY to unlock it PERFORM THE FIRST SAMPLE The object of this exercise is to check that everythi...

Страница 18: ...e are many additional steps and procedures that you can do whilst running an actual CV sample You will find these How to Steps via the On line Help Guide available on the website www ddscalorimeters c...

Страница 19: ...rocedure with the second vessel The calibration data set is stored in the vessel calibration history for the chassis number ROUTINE SAMPLE DETERMINATION The procedure is the same If you perform multip...

Страница 20: ...be binding on dds unless recorded in writing and signed by a duly authorised officer of the company dds agrees to repair and replace with a new or remanufactured part any part other than those exclud...

Страница 21: ...hat is sent to dds for Repair is tested and checked and leaves dds s Factory in 100 working order It is the Owner s responsibility to inspect any repaired product on receipt thereof and confirm in wri...

Страница 22: ...AME OWNER S CUSTOMER S COMPANY NAME AUTHORISED BY INSTALLED AT TEL NO FAX NO CONTACT PERSON INSTALLED BY DATE INSTALLED REPRESENTATIVE OF DEALER AGENT CUSTOMER ORDER NUMBER AND DATE INSTALLATION DETAI...

Отзывы: