S O F T W A R E
Data Device Corporation
SB-3642 Manual
Rev D – 4/19
25
5.1.3 Motion Feedback LabVIEW SDK (SB-36030SL)
The card is supplied with the SB-36030SL Motion Feedback LabVIEW support
package. This software development kit includes a set of VIs that provides the user
with a hardware abstraction layer for the DDC Motion Feedback hardware in a
LabVIEW environment. The Package includes 3 layers of VIs which enable easy
application development. Functional user samples are included for common functions.
5.1.4 Troubleshooting the Installation
Usually the installation will be successful, and the self-test within the sample programs
will pass. There are, however, some situations that can cause problems during the
installation. The most common are detailed below.
An error is returned when an attempt is made to run any of the samples. This fault is
almost always related to an incorrectly assigned device number. Be sure that a device
number was correctly assigned through the DDC Card Manager.
If an error is encountered and the device number appears to be correctly assigned,
check the operating system. The BIOS setting for a PnP operating system is
sometimes set to YES, which can cause a problem. This BIOS option must be set for
NO. The operating system, as well as all hardware on your system, will still maintain
PnP compatibility; it will not be necessary to manually configure resources for PnP
cards.