background image

Basic Locating

1.

Find the Front Locate Point (FLP) and the Rear Locate Point (RLP) by
centering the target ball in the box. Mark the positions.

2.

At the FLP, hold trigger for predicted depth reading. The Reference
Indicator

R

icon will appear. The Locate Line (LL) may not appear if

this step is skipped.

3.

Find the LL by centering the line in the box between the FLP and the
RLP (see Locate Mode screen on next page).

4.

View depth by holding the trigger at the LL on the line connecting the
FLP and the RLP.

5.

Holding the trigger longer than five seconds enables

MAX Mode

(see

page 

6

). MAX Mode does not have to be at LL or FLP.

Transmitter Signal Field Geometry

Level Transmitter

1. Side view

2. RLP: Rear Locate Point
3. LL: Locate Line
4. FLP: Front Locate Point

Pitched Transmitter

1. Bird's-eye view

(top down)

2. Drill Rig
3. Side view (underground)
4. RLP: Rear Locate Point
5. LL: Locate Line
6. Transmitter (Tx)
7. Bore path
8. FLP: Front Locate Point

FLP and RLP are not equidistant from the LL when the transmitter is
pitched. For more information, see the

DigiTrak DigiGuide App

,

Advanced Topics > Steep and Deep

.

- 7 -

Содержание DigiTrak Falcon F2

Страница 1: ...Telemetry channel 2 Transmitter Tx band up down 3 Locator battery status 4 Locate Mode 5 Power off 6 Calibration 7 Height Above Ground HAG 8 Settings 9 Transmitter Frequency Optimization FO Toggle to...

Страница 2: ...number 4 Maximum noise level 5 Up band 6 Down band 7 Scan rescan 8 Pair 9 Exit Frequency Optimization Results Run the FO for each new project to select an optimal set of frequencies for each band ever...

Страница 3: ...oth will pair at the same time and the locator will be set to use the Down band first a Install transmitter Tx batteries and endcap the increase in FO noise readings shows the Tx is on b Select Pair t...

Страница 4: ...within 5 Access AGR directly on the Calibration menu Calibrate and check AGR for both new bands If you selected two bands repeat steps 5 6 Calibration and AGR for the second band An error symbol will...

Страница 5: ...Tx changes bands data disappears from the locator Below Ground Mid Bore 10 2 7 Roll Method Disable Roll Offset if enabled 1 Roll clock wise to approx 10 o clock 1 CP Wait 10 18 seconds 2 Roll clock wi...

Страница 6: ...under the roll clock is full Always take three MAX Mode readings all three must be consistent See the DCI DigiGuide App for important information on this feature Signal Attenuation Signal attenuation...

Страница 7: ...at the LL on the line connecting the FLP and the RLP 5 Holding the trigger longer than five seconds enables MAX Mode see page 6 MAX Mode does not have to be at LL or FLP Transmitter Signal Field Geom...

Страница 8: ...view 3 Line in the Box at LL 4 HAG on 5 MAX Mode timer 6 MAX Mode icon 7 Tx depth Depth Screen Trigger held at FLP 1 Reference indicator 2 Ball in the Box 3 Roll pitch update meter 4 Tx predicted dept...

Отзывы: