Changing Locator Frequency Band

If you change bands on your transmitter, you must also do so on your
locator. At the Locate Mode screen, hold the toggle right briefly to open
the Band Selection window. Select the Up or Down band, or select

Locate

Mode

, to return to the Locate Mode screen without changing bands.

The data should begin displaying as transmission resumes in the new
band.

MAX Mode

MAX Mode™

helps obtain depth/data readings in high-interference

areas and at the edge of the Tx's range, when readings are unstable.

• The drill head must remain stationary during MAX Mode readings.

• Hold the trigger at least five seconds to enter MAX Mode.

Do not consider the data reliable unless the reading is
stable before the MAX Mode timer bar under the roll clock is
full.

• Always take three MAX Mode readings; all three must be

consistent.

See the

DCI DigiGuide App

for important information on this feature.

Signal Attenuation

Signal attenuation may occur due to excessive interference or if the
locator is within 8 feet of the Tx, such as when locating at a shallow depth.

If an

A

icon appears on the roll indicator for depths shallower than 8 feet,

you can ignore the warning. This is normal.

If the

A

icon and signal flashes on the Locate Mode screen or appears on

the Frequency Optimization screen, there is extreme interference. Depth
and locate points could be compromised and the locator will not calibrate.
Relocate to a quieter location before recalibrating.

For detailed information, see the DCI DigiGuide™ App. If you have questions,

contact Customer Service at 425.251.0559 or 800.288.3610 US/CA.

Watch our DigiTrak

®

training videos at

www.YouTube.com/DCIKent

Printed:

11/14/2019

- 6 -

Содержание DigiTrak Falcon F2

Страница 1: ...Telemetry channel 2 Transmitter Tx band up down 3 Locator battery status 4 Locate Mode 5 Power off 6 Calibration 7 Height Above Ground HAG 8 Settings 9 Transmitter Frequency Optimization FO Toggle to...

Страница 2: ...number 4 Maximum noise level 5 Up band 6 Down band 7 Scan rescan 8 Pair 9 Exit Frequency Optimization Results Run the FO for each new project to select an optimal set of frequencies for each band ever...

Страница 3: ...oth will pair at the same time and the locator will be set to use the Down band first a Install transmitter Tx batteries and endcap the increase in FO noise readings shows the Tx is on b Select Pair t...

Страница 4: ...within 5 Access AGR directly on the Calibration menu Calibrate and check AGR for both new bands If you selected two bands repeat steps 5 6 Calibration and AGR for the second band An error symbol will...

Страница 5: ...Tx changes bands data disappears from the locator Below Ground Mid Bore 10 2 7 Roll Method Disable Roll Offset if enabled 1 Roll clock wise to approx 10 o clock 1 CP Wait 10 18 seconds 2 Roll clock wi...

Страница 6: ...under the roll clock is full Always take three MAX Mode readings all three must be consistent See the DCI DigiGuide App for important information on this feature Signal Attenuation Signal attenuation...

Страница 7: ...at the LL on the line connecting the FLP and the RLP 5 Holding the trigger longer than five seconds enables MAX Mode see page 6 MAX Mode does not have to be at LL or FLP Transmitter Signal Field Geom...

Страница 8: ...view 3 Line in the Box at LL 4 HAG on 5 MAX Mode timer 6 MAX Mode icon 7 Tx depth Depth Screen Trigger held at FLP 1 Reference indicator 2 Ball in the Box 3 Roll pitch update meter 4 Tx predicted dept...

Отзывы: