5. Calibrate Both Bands

Calibration in an interference-free environment
is required after any optimization.

a.

Place the Tx in a housing on level ground
10 feet from locator as shown.

b.

From the Main menu, select

Calibration

>

1 PT CAL

and calibrate each new band.

After the calibration, the Above Ground Range
(AGR) screen opens automatically.

6. Check Above Ground Range (AGR)

Always check AGR with a tape measure to
verify depth readings on each band at various
distances up to the maximum expected bore
depth. Distance readings should be within ±5%.

Access AGR

directly on the

Calibration

menu. Calibrate and check AGR for both new
bands.

If you selected two bands, repeat steps 5-6 (Calibration and AGR) for the
second band. An error symbol will display in the roll indicator on the Locate

screen until a 1 point calibration is completed for the current band.

Settings Menu

Use the Settings menu

to set the depth units, pitch units, telemetry

channel, contrast, LOC security options, level check, and roll offset.

Height-Above-Ground (HAG) Menu

Height-Above-Ground (HAG) is the distance from the ground to the

bottom of the locator while it is held. Setting HAG

on the Main menu

lets you take accurate below-ground depth measurements without having
to place the locator on the ground.

- 4 -

Содержание DigiTrak Falcon F2

Страница 1: ...Telemetry channel 2 Transmitter Tx band up down 3 Locator battery status 4 Locate Mode 5 Power off 6 Calibration 7 Height Above Ground HAG 8 Settings 9 Transmitter Frequency Optimization FO Toggle to...

Страница 2: ...number 4 Maximum noise level 5 Up band 6 Down band 7 Scan rescan 8 Pair 9 Exit Frequency Optimization Results Run the FO for each new project to select an optimal set of frequencies for each band ever...

Страница 3: ...oth will pair at the same time and the locator will be set to use the Down band first a Install transmitter Tx batteries and endcap the increase in FO noise readings shows the Tx is on b Select Pair t...

Страница 4: ...within 5 Access AGR directly on the Calibration menu Calibrate and check AGR for both new bands If you selected two bands repeat steps 5 6 Calibration and AGR for the second band An error symbol will...

Страница 5: ...Tx changes bands data disappears from the locator Below Ground Mid Bore 10 2 7 Roll Method Disable Roll Offset if enabled 1 Roll clock wise to approx 10 o clock 1 CP Wait 10 18 seconds 2 Roll clock wi...

Страница 6: ...under the roll clock is full Always take three MAX Mode readings all three must be consistent See the DCI DigiGuide App for important information on this feature Signal Attenuation Signal attenuation...

Страница 7: ...at the LL on the line connecting the FLP and the RLP 5 Holding the trigger longer than five seconds enables MAX Mode see page 6 MAX Mode does not have to be at LL or FLP Transmitter Signal Field Geom...

Страница 8: ...view 3 Line in the Box at LL 4 HAG on 5 MAX Mode timer 6 MAX Mode icon 7 Tx depth Depth Screen Trigger held at FLP 1 Reference indicator 2 Ball in the Box 3 Roll pitch update meter 4 Tx predicted dept...

Отзывы: