Troubleshooting
69
•
The communication parameters between the PC/terminal
and the local (“Client”) EtherPath match.
•
The communication parameters between the serial port
device and the remote (“Server”) EtherPath match.
P5:
The EtherPath's IP Address is unknown. Is there any way of
finding it?
S5:
Follow this procedure:
•
Yes, see the chapter on using
Terminal Configuration
.
•
Press the configuration button and use a terminal
connection to read the existing configuration.
P6:
Why does the "Server Mode" EtherPath close the TCP/IP
connnection to the "Client Mode" EtherPath (or other client
program).
S6:
The "Server Mode" EtherPath will disconnect the link if it does
not receive any packets from the "Client Mode" EtherPath (or
other client program)
within a 3 minute period or if hardware
pin 6 is lowered. See Appendix B for more details. The Keep-
Alive frequency configuration value affects this operation.
P7:
The connection works, but is too slow.
S7:
If in
Transmit timer mode,
lower the transmit timer to send
packets more frequently. 20 to 30 msec. is a good range for
many users. If in
Idle timeout mode
perhaps the serial data rate
may be increased so characters arrive at the EtherPath faster.