Operation
23
Flow Control
The choices are “None”, “XON/XOFF”, and “RTS/CTS”. It is
common to use NONE for installation troubleshooting, then set it
correctly to match the connected device. If RTS/CTS is used, the
cables must have handshake lines wired correctly. RTS Toggle is a
handshake mode commonly used with half duplex modems. The
RTS output is asserted when the unit has data to transmit and it will
remain asserted for approximately 5ms after the last character has
been transmitted. The CTS signal controls output flow.
Baud Rate
Speeds between 300 bps and 230.4Kbps are supported.
Parity
The choices are “None”, “Odd”, or “Even”.
Data Bits
The choices are 7 or 8. This does NOT include the parity bit. The
two most common settings are 7 bit PLUS appropriate parity or 8
bit with NO parity. Default is 8 bits.
Stop Bits
The choices are 1 or 2. Commonly use 1.
Pin 6 Control
If Forced On, the EtherPath responds as if interface pin 6 is always
high. If From Interface, its condition is a read from the RS-232
cabling must be correct for proper operation.
Dial Mode
The choices are “ATD” or “Hardware”. This configures the
EtherPath, when in client mode, to connect to a remote device when