background image

3

 

Easy to setup and maintain

 

Web browser, telnet or serial port configuration

 

Statistics, logging and diagnostic tools

 

Can authenticate with RADIUS server

 

Stand-alone or Rack Mounting

 

120, 220 VAC, 12, 24, 48 and 125 VDC options

EST 9600 Front View

EST 9600 Rear View (48 VDC Version)

Содержание EST-9600

Страница 1: ...DICATORS 6 SECTION 4 INSTALLATION 7 SECTION 5 QUICK SETUP GUIDE 8 SECTION 6 SETUP 11 SECTION 7 INTERFACE SIGNALS AND CABLING 22 SECTION 8 TROUBLESHOOTING 26 SECTION 9 WARRANTY 27 Data Comm for Busines...

Страница 2: ...the EST 9600 makes it simple and easy to accomplish The EST 9600 supports RS 232 serial interface speeds up to 230 Kbps RS 530 speeds up to 2048 Kbps To deliver HDLC traffic via Ethernet in as close...

Страница 3: ...er telnet or serial port configuration Statistics logging and diagnostic tools Can authenticate with RADIUS server Stand alone or Rack Mounting 120 220 VAC 12 24 48 and 125 VDC options EST 9600 Front...

Страница 4: ...4 APPLICATION...

Страница 5: ...ication internal name password database or up to two external customer supplied RADIUS servers Encryption 128 bit AES or NONE Once connection is established tunnels use UDP to deliver packets Web brow...

Страница 6: ...be Down 4 Must be Down INDICATORS Front Indicator Condition Meaning Power ON Power to unit Status OFF ON Set for Internal Clock Set for External Clock Sync Flashing Sync Port Data Activity Setup Flas...

Страница 7: ...ia the Serial Setup port via Telnet or via a Web Browser The serial port can be enabled or disabled using switch 2 on the rear of the unit Switch 2 must be up for the serial management port to be acti...

Страница 8: ...nd Activate The EST 9600 can tunnel in encrypted mode or with no encryption Menu selection 2 is used if you wish to change from the default of Encryption ON to NONE For Tunnel Mode menu selection 3 se...

Страница 9: ...or details on changing the clock source jumpers The internal jumpers are accessed by removing the 2 Phillips head screws that hold on the front panel Remove the 2 screws and slide the circuit board fo...

Страница 10: ...P Frame Relay X 25 data NRZI is often used with IBM SDLC protocols After making all the necessary changes select item 8 from the main menu Save and Activate Remember that after changing the IP address...

Страница 11: ...nal emulation software as follows Rate 9600 Data Bits 8 Stop Bits 1 Parity None Flow Control None disabled Apply power to the EST USING THE SETUP PORT After the unit boots press Enter An Enter name pr...

Страница 12: ...enu Press for help Set HDLC Tunnel Values Common Passphrase Encryption AES 128 Tunnel Mode drop TCP UDP Port 22 Tunnel Values 1 Common Passphrase 2 Encryption 0 AES 128 1 none 3 Tunnel Mode 0 host 1 d...

Страница 13: ...llowed Web IP Address 1 Allowed Web IP Netmask 1 Allowed Web IP Address 2 Allowed Web IP Netmask 2 Tunnel Values Common Passphrase Encryption AES 128 Tunnel Mode drop TCP UDP Port 22 Primary Host Valu...

Страница 14: ...Mask 255 255 255 0 Default Gateway Host Name noname Domain Primary Name Server Secondary Name Server press return for more ESC to quit HDLC Values Sync Mode Clock Source internal Internal Clock Rate...

Страница 15: ...The left side shows the main menu selections The right hand column shows the sub menus for the main menu selections that have sub menus All pages with fields that can filled in have help screens that...

Страница 16: ...d are set Admin Access Control Ping can be enabled or disabled Telnet access can be enabled or disabled The Telnet setup port can be changed from the default 8000 to any other port Web browser access...

Страница 17: ...et All Defaults puts all the settings back to the factory default state Config File is a way to save the configuration file to a PC or to load a working configuration file from a PC into the EST 9600...

Страница 18: ...sub menu is used to set the Common Passphrase Advanced Tunnel Configuration sets the idle disconnect value and the keep alive value Authorized Drop Names Passphrases is a listing of the drop names and...

Страница 19: ...s useful when a radius server is used as a centralized authorization device In installations with many EST 9600 units a radius server approach makes it easier to change EST 9600 host devices in the ev...

Страница 20: ...um Transmit Unit MTU The EST 9600 defaults to internal sync mode clock source There are 15 clock speed choices ranging from 1200 bps to 2048000 bps TOOLS The Tools include Ping Traceroute and a Packet...

Страница 21: ...CTIVATE Activate Changes is used to move configuration changes to the active state If changes are activated but not stored in the next step the changes will only be active until the next reboot and or...

Страница 22: ...front panel in place and remove the circuit board Move the jumper to the position farthest away from the port connector and reassemble the unit RS 232 RJ 45 Pin Signal In Out 1 Receive Clock IN OUT 2...

Страница 23: ...mit OUT 2 Transmit OUT 3 Receive IN 6 Receive IN Setup Port RS 232 RJ 45 Pin Signal In Out 1 Data Set Ready OUT 2 Data Carrier Detect OUT 3 Busy IN 4 Signal Ground 5 Receive Data OUT 6 Transmit Data I...

Страница 24: ...Synchronous Port RS 232 EST DCE DTE RJ 45 DB 25 DB 25 RS 530 EST RS 530 RJ 45 DB 25 17 or 17 15 or 15 5 or 4 7 or 7 2 or 3 3 or 2 4 or 5 8 or 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 2 14 3 17 9 16 15 12 4...

Страница 25: ...25 Setup Port To a TERMINAL EST Terminal RJ 45 DB 25P To a PC using terminal emulation EST Computer RJ 45 DE 9S DB 25S 7 3 2 4 5 6 5 or 7 2 or 3 3 or 2 4 5 6...

Страница 26: ...wing the equipment at both the host and remote ends and the phone lines or in house wiring Use this as a reference to note your observations test steps and test results A picture keeps you focused and...

Страница 27: ...mages etc DCB liability shall not exceed the original purchase price All equipment returned for repair must be accompanied by a Returned Material Authorization RMA number To receive an RMA number call...

Отзывы: