![DCB EST-9600 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/dcb/est-9600/est-9600_manual_4007274022.webp)
22
7.
INTERFACE SIGNALS AND CABLING
CONNECTOR AND PIN REFERENCE
RJ-45 Plug and Jack
PORT INTERFACE
Synchronous Port
The Synchronous port can be either RS-232 or RS-530 depending on the position of a jumper inside
the unit. This jumper (P7) is located behind the synchronous port connector (P8) and is defaulted to
RS-232. To change the port to RS-530, remove the two screws that hold the front panel in place and
remove the circuit board. Move the jumper to the position farthest away from the port connector
and reassemble the unit.
RS-232 (RJ-45)
Pin
Signal
In/Out
1
Receive Clock
IN/OUT
2
Transmit Clock
IN/OUT
3
Clear to Send
IN
4
Signal Ground
-----
5
Transmit Data
OUT
6
Receive Data
IN
7
Request to Send
OUT
8
Data Carrier Detect
IN
RS-530/422 (RJ-45)
Pin
Signal
In/Out
1
Transmit Data A (
−
)
OUT
2
Transmit Data B (+)
OUT
3
Receive Data A (
−
)
IN
4
Receive Clock A (
−
)
IN/OUT
5
Receive Clock B (+)
IN/OUT
6
Receive Data B (+)
IN
7
Transmit Clock A (
−
)
IN/OUT
8
Transmit Clock B (+)
IN/OUT
1 2 3 4 5 6 7 8