9
3.4
Inspect the project table after installation
No.
Inspection item
Yes
No
Remarks
1
Whether the working voltage is
consistent with the requirements of
the equipment
2
Whether the components are
installed correctly
3
Whether the bolts, screws, nuts are
tightened
Note:
Please fill in the inspection item list after the installation is finished.
3.5
Commissioning and debugging
3.5.1
Commissioning
◇
After the machine installation and before the connection with the power supply, please
do make sure the user's power supply and air supply meet the requirements of the
machine.
◇
The machine is connected to the circuit. The circuit must be standard equipped with a
fuse, ground wire and the automatic circuit breaker of 25A according the operation
rule(
Note:
Only the professional personnel can do the circuit work). The power plug of
the tire changer should be provided by the customer. (
Note:
The standard circuit of the
plug is 16A, but it must meet its Working Voltage).
◇
As shown in Figure 7, the air supply is connected to machine by a pipe connector
(Q) on the side of Oil Drier.
Picture 7
Q
Содержание C896CMLL
Страница 20: ...7 0 Explosive View ...