background image

4

Ÿ

If there is flow inside the tank, support the piping appropriately. The pipes must 
be installed such as to prevent air lock, if unavoidable, an air release valve must 
be installed wherever such air pockets are likely to develop.

Ÿ

The end of discharge pipe should not be submerged as back flow will result 

For automatic pumps, install a oat switch as shown in Fig-
1. The pump may not start if the oat switch touches the 
wall of the water tank or the piping.

WARNING

Ÿ

The Pump should be connected to either a rigid pipe or hose. The diameter 
should be no less than the pump outlet.

Ÿ

To avoid dry running, on manual pumps an external float switch can be installed 
as shown in Fig-2. Always ensure to maintain a safe operating water level.

Ÿ

Ensure to never lift the pump by the main supply cable or permanent damage 
will occur.

Ÿ

All installations must be provided with an isolator to cut off mains power supply 
and coarse current protection in the form of a fuse or MCB rated at 2-3 times 
the full load current as given on the pump plate.

Ÿ

Ensure that the power supply rating complies with the specification on the pump 
rating plate.

Ÿ

Electrical connections must be made according to details in the pump junction 
box  cover  and  effective  earthing  must  be  provided  according  to  local 
regulations.

Ÿ

Single-phase motors are protected against overloads by a thermal overload 
fitted  in  the  motor  windings.  Three  phase  motors  should  be  installed  with 
remote starter.

Ÿ

Regularly  check  the  current  readings.  If  fluctuating,  foreign  matter  may  be 
clogging the pump. Also if pump output reduces, foreign matter may be present 
and the pumps hydraulic end should be checked and cleaned.

Ÿ

Measure the insulation resistance monthly. The value should be more than 1M 
ohm.

3.  ELECTRICAL CONNECTIONS

The installer is responsible for making electrical connections to 
the mains supply in compliance with relevant local regulations. 
Ensure that a professional electrician carries out the electrical 
connections and that the following guidelines are followed:-

WARNING

4.  MAINTENANCE

Содержание DWW Series

Страница 1: ...DWW DWV DWC DRAINAGE PUMPS Installation Operating Manual DWW 30M 50M 75M DWW 05A DWW 10A 20A DWV 30M 50M 75M DWV 05A 10 DWC...

Страница 2: ......

Страница 3: ...PUMP SPECIFICATIONS 1 1 2 INSTALLATION 3 ELECTRICAL CONNECTIONS 3 4 MAINTENANCE 4 4 TROUBLE SHOOTING 5 5 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted WARRANTY 6 7...

Страница 4: ...75M DWV 50M DWV 30M DWC 20A DWC 10A DWV 10A DWV 05A 3 FLOW m hr HEAD m 6 0 5 10 15 20 12 18 30 24 36 42 DWC Congratulations on selecting a Dayliff DW Pump They are manufactured to the highest standard...

Страница 5: ...clogging cast iron pump casing double mechanical seal and NBR oil seal They are designed for fixed installation with discharge connection suitable for guide rail mounting All pumps are supplied with 1...

Страница 6: ...period of time in a dry condition or at the lowest water level the motor will overload and shut down Prolonged overheating will shorten pump service life Do not start the pump again in such a situati...

Страница 7: ...protection in the form of a fuse or MCB rated at 2 3 times the full load current as given on the pump plate Ensure that the power supply rating complies with the specification on the pump rating plate...

Страница 8: ...a qualified electrician should be consulted To prolong the service life of the mechanical seal replace the oil in the mechanical seal chamber once a year Water mixed with the oil or cloudy mixtures ar...

Страница 9: ...ign matter Foreign matter clogging pump Replace impeller Worn out impeller 6 PROBLEM POSSIBLE CAUSE SOLUTION Over current Wait for supply to stabilise Unbalanced current and voltage Significant voltag...

Страница 10: ...ility In lieu of any warranty condition or liability implied by law the liability of Dayliff in respect of any defect or failure of equipment supplied is limited to making good by replacement or repai...

Страница 11: ......

Страница 12: ...INS253B 10 14...

Отзывы: