Pump Data

2.  INSTALLATION

Enclosure Class:

 F         

Insulation Class:

 IP68              

Speed:

2900rpm

Weight

(kg)

Model

Outlet

Voltage

(V)

HP

Power

kW

Current

(A)

H1

Dimensions (mm)

H2

3x415

3

2.2

5.2

3”

35

153

1x240

0.1

0.75

6

3”

35

35

568

18.5

464

35
57
63

35

24

14

63

57

13.5

169

84

536
556
605
645

451

373

115

64

410

638
678

2
3
5

7.5

1.5

12

2.2

5.2

3”

3.7

8.6

4”

5.5

12

4”

3”

1

0.75

6

2”

1x240
1x240
1x240

3x415
3x415
3x415

1x240

3x415
3x415

0.5

0.37

4

2”

7.5

5

0.5

5.5

3.7

0.37

12

8.6

4

4”

4”

2”

50

50

35

6
6
6
6
6
6

1x240

1x240

2

1

1.5

0.75

12

6

22

22

164
164

215
215

155

97

541

416

220
220

2”

2”

If  the  pump  is  operated  continuously  for  an  extended 
period of time in a dry condition or at the lowest water 
level, the motor will overload and shut down. Prolonged 
overheating will shorten pump service life. Do not start the 
pump again in such a situation until after the motor has 
completely cooled.

WARNING

Ÿ

Lower the pump into the well by attaching a 
chain or rope to the grip to install the pump. 
For DWV models firmly locate the discharge 
connection on a base in the sump and amount 
to guide rails suitably supported at the sump 
top level. The pump rail guide should then be 
slid  down  the  pipes  until  the  pump  is  firmly 
seated on the discharge connection.

Ÿ

The pump must not be installed on its side or 
operated under dry condition. Ensure that it is 
installed upright on a secure base and is not 
resting in silt or sand _____ normal operation.

Ÿ

Install the pump at a location in the tank where 
there is least turbulence.

Operating Water Level

Stop Water Level

DWW/DWC

Fig 1

H1

H2

OFF

Fig 2

ON

DWV

Содержание DWW Series

Страница 1: ...DWW DWV DWC DRAINAGE PUMPS Installation Operating Manual DWW 30M 50M 75M DWW 05A DWW 10A 20A DWV 30M 50M 75M DWV 05A 10 DWC...

Страница 2: ......

Страница 3: ...PUMP SPECIFICATIONS 1 1 2 INSTALLATION 3 ELECTRICAL CONNECTIONS 3 4 MAINTENANCE 4 4 TROUBLE SHOOTING 5 5 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted WARRANTY 6 7...

Страница 4: ...75M DWV 50M DWV 30M DWC 20A DWC 10A DWV 10A DWV 05A 3 FLOW m hr HEAD m 6 0 5 10 15 20 12 18 30 24 36 42 DWC Congratulations on selecting a Dayliff DW Pump They are manufactured to the highest standard...

Страница 5: ...clogging cast iron pump casing double mechanical seal and NBR oil seal They are designed for fixed installation with discharge connection suitable for guide rail mounting All pumps are supplied with 1...

Страница 6: ...period of time in a dry condition or at the lowest water level the motor will overload and shut down Prolonged overheating will shorten pump service life Do not start the pump again in such a situati...

Страница 7: ...protection in the form of a fuse or MCB rated at 2 3 times the full load current as given on the pump plate Ensure that the power supply rating complies with the specification on the pump rating plate...

Страница 8: ...a qualified electrician should be consulted To prolong the service life of the mechanical seal replace the oil in the mechanical seal chamber once a year Water mixed with the oil or cloudy mixtures ar...

Страница 9: ...ign matter Foreign matter clogging pump Replace impeller Worn out impeller 6 PROBLEM POSSIBLE CAUSE SOLUTION Over current Wait for supply to stabilise Unbalanced current and voltage Significant voltag...

Страница 10: ...ility In lieu of any warranty condition or liability implied by law the liability of Dayliff in respect of any defect or failure of equipment supplied is limited to making good by replacement or repai...

Страница 11: ......

Страница 12: ...INS253B 10 14...

Отзывы: