background image

DWW

The Dayliff DWW range of open impeller portable submersible pumps are designed 
for  pumping  waste  water  containing  particles  and  impurities  in  industrial  and 
domestic applications. They feature cast iron impellers and pump bodies, double 
mechanical seals, NBR oil seals and stainless steel strainers and are supplied with 
10m of cable. Single phase pumps up to 1.5kW are supplied with level switches for 
automatic operation while 3 phase pumps require external switching control.

DWV

The Dayliff DWV range of submersible pumps are designed to handle industrial and 
domestic waste water and sewage and are especially suitable for pumping water 
containing  a  high  proportion  of  solid  particles  including  threads  and  fibres.  The 
pumps  are  of  heavy  duty  construction  featuring  cast  iron  vortex  impeller  which 
minimises clogging, cast iron pump casing, double mechanical seal and NBR oil seal. 
They are designed for fixed installation with discharge connection suitable for guide 
rail mounting. All pumps are supplied with 10m of H07RNF cable.

DWC

The Dayliff DWC range of heavy duty submersible pumps are designed to handle 
industrial  and  domestic  waste  water  and  sewage  with  a  specially  designed  cutter 
impeller. They are suitable for pumping water containing a high proportion of solid 
particles  including  threads  and  fibres.  Pump  construction  is  cast  iron  semi-open 
impeller with Tungsten Carbide cutting edge, cast iron casing, double mechanical 
seal and NBR oil seal. The pumps are designed for free standing installation and are 
supplied  complete  with  10m  of  H07RNF  cable  and  level  switches  for  automatic 
operation.

OPERATING CONDITIONS

Pumped  liquids:

  Thin,  chemically  non-aggressive  liquids,  containing  some 

impurities and fibres

0

Max. Liquid temperature:

 +40 C

Max. Operating Depth:

 10m 

Min Immersion Depth:

 

DWW 

-132mm

                                       

DWV

 - 160mm

                                       

DWC

 - 310mm

2

Содержание DWW Series

Страница 1: ...DWW DWV DWC DRAINAGE PUMPS Installation Operating Manual DWW 30M 50M 75M DWW 05A DWW 10A 20A DWV 30M 50M 75M DWV 05A 10 DWC...

Страница 2: ......

Страница 3: ...PUMP SPECIFICATIONS 1 1 2 INSTALLATION 3 ELECTRICAL CONNECTIONS 3 4 MAINTENANCE 4 4 TROUBLE SHOOTING 5 5 INDEX Davis Shirtliff Ltd 2020 Contents herein are not warranted WARRANTY 6 7...

Страница 4: ...75M DWV 50M DWV 30M DWC 20A DWC 10A DWV 10A DWV 05A 3 FLOW m hr HEAD m 6 0 5 10 15 20 12 18 30 24 36 42 DWC Congratulations on selecting a Dayliff DW Pump They are manufactured to the highest standard...

Страница 5: ...clogging cast iron pump casing double mechanical seal and NBR oil seal They are designed for fixed installation with discharge connection suitable for guide rail mounting All pumps are supplied with 1...

Страница 6: ...period of time in a dry condition or at the lowest water level the motor will overload and shut down Prolonged overheating will shorten pump service life Do not start the pump again in such a situati...

Страница 7: ...protection in the form of a fuse or MCB rated at 2 3 times the full load current as given on the pump plate Ensure that the power supply rating complies with the specification on the pump rating plate...

Страница 8: ...a qualified electrician should be consulted To prolong the service life of the mechanical seal replace the oil in the mechanical seal chamber once a year Water mixed with the oil or cloudy mixtures ar...

Страница 9: ...ign matter Foreign matter clogging pump Replace impeller Worn out impeller 6 PROBLEM POSSIBLE CAUSE SOLUTION Over current Wait for supply to stabilise Unbalanced current and voltage Significant voltag...

Страница 10: ...ility In lieu of any warranty condition or liability implied by law the liability of Dayliff in respect of any defect or failure of equipment supplied is limited to making good by replacement or repai...

Страница 11: ......

Страница 12: ...INS253B 10 14...

Отзывы: