OC-B Controller Display

Fig 5

No.

1

Switch ON & OFF

2

3

Part

Description

Dual function button push to select steam on demand mode 
or to drain the generator manually when not steaming

On

Off

On

Off

Light

Light

Temperature Display

Time Display

Push to operate lights

Drain

Drain

Fan

Mode

Mode

Enter

4

Dual  function  button  used  when  steaming  to  set  the 
time/temperature 

5

6

Decrease button

Increase button

Set

Clean

Set

Clean

5

1

2

5

4

16

15

9

14

13

3

6

7

17

10

8

11

12

Light

Clean

Fan

Water  Drain Mode Heating

Overheating

Содержание DSTEAM90

Страница 1: ...Steam Generator STEAM GENERATOR...

Страница 2: ......

Страница 3: ...10 4 1 Steam Room Design 7 6 TROUBLE SHOOTING 14 8 TERMS OF WARRANTY 17 Davis Shirtliff Ltd 2022 Contents herein are not warranted 5 OPERATION 12 7 MAINTENANCE 16 5 2 Setting Time Temperature 13 5 3...

Страница 4: ...g a steam head and auto drain valve Provision for auto descaling is provided OPERATING CONDITIONS Water Pressure Min 0 25Bar Max 8Bar Water Quality Hardness less than 50ppm CaCo above which regular de...

Страница 5: ...where both the electrical power and water supply can be isolated in an emergency WARNING The minimum water inlet pressure is 0 25 bar and a maximum of 8 bar working pressure should not exceed 5 bar W...

Страница 6: ...led on level ground WARNING The Steam generator should not be in close proximity to hazardous substances WARNING The size of heater required to heat a particular size of steam room is dependent on typ...

Страница 7: ...Insulation Material 7 Detect the water level Water Level Probe 8 Steam Outlet Steam Outlet 9 13 Operates if the pressure in the boiler exceeds 10 2bar 10 11 12 Pressure Relief Valve 0 To protect boile...

Страница 8: ...lly when not steaming On Off On Off Light Light Temperature Display Time Display Push to operate lights Drain Drain Fan Mode Mode Enter 4 Dual function button used when steaming to set the time temper...

Страница 9: ...Drain LED 13 Operation mode indicator red is for steam on demand mode and green for conventional timing Mode LED 14 Green indicates heating is on red indicates the required temperature Heating LED 15...

Страница 10: ...W will heat up to 3 1m of air For dense materials such as stones and ceramics which conduct heat more 3 rapidly allow for up to 2kW per m of air Hot air rises so restricting the height to around 2 met...

Страница 11: ...e included in the controller to set working times in regular intervals of 30minutes The steam generator should be installed in a dry well ventilated place in close proximity to the steam room It can b...

Страница 12: ...fort it s h o u l d b e a t t h e farthest place from the seat STEAM GENERATOR Valve Water Level Probe Overheat Switch According to the location it may be necessary to attach an additional length of p...

Страница 13: ...am room at approximately 1 2 to 1 5 meters high and away from the door respective Use a 4mm screw to fix it in place and connect to the wire from the controller 10 Temperature Sensor 4 Screw Installat...

Страница 14: ...Fig 10 11 9kW Steam Generator Circuit Diagram 12 15kW Steam Generator Circuit Diagram Fig 11...

Страница 15: ...the water inlet valve will turn off 3 After a few minutes of operation the generator will begin steaming for small steam generator 2 3 minutes and about 3 5 minutes for larger generators 4 Press the k...

Страница 16: ...altering the settings of the JP1 pins on the circuit board Fan Enter Set Clean 5 2 Setting Time and Temperature 0 The steam generator default settings are 40 C temp and 1 hour of operation which can b...

Страница 17: ...with clean water when the cycle is complete the drain LED will go off 2 Ensure there is sufficient descaling solution in the container to completely fill the boiler when liquid level reaches set poin...

Страница 18: ...here is no steam being produced 1 Replace main circuit board 2 Replace relay circuit board 3 Replace heating elements 1 Main Circuit Board Faulty 2 Relay Circuit Board Faulty 3 Heating Elements Faulty...

Страница 19: ...sulting in leaks from around the elements The extent of the problem will vary according to the degree of hardness in the local water supply It is recommended to use water softener NOTE All commercial...

Страница 20: ...ranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by replace...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...INS498A 04 22...

Отзывы: