12
Steam on Demand Function
Commercial operators may wish to take advantage of the steam on demand function
which allows bathers to press the steam on demand button located inside the steam room
after which the generator will operate for 30 minutes then stop until activated again.
To operate the steam on demand function install the controller inside the plant room
alongside the generator then fit the push button supplied in a convenient location inside
the steam room and connect to the controller with the cable provided.
5. OPERATION
Once the installation has been completed and checked, turn on the power and water
supply and carry out the following procedure
1. On the control panel press the “ “ key , the key has a time-lapse function, long
press for 1 second, the time and temp windows will display the data.
2. Open the water inlet valve and water will enter the boiler, the indicator LED turns red.
When the water level rises to the low water sensor level the elements will switch on and
the heating indicator LED will turn on. When the high water sensor is reached the
water inlet indicator LED changes to green and the water inlet valve will turn off.
3. After a few minutes of operation the generator will begin steaming, for small steam
generator 2-3 minutes and about 3-5 minutes for larger generators.
4. Press the “ “, key again and the controller turns off. The display turns off and
steam stops being generated there will also be no data on display.
5. Press the “ “ key once more (temp and time display again) after a few seconds the
generator will begin producing steam again. Let the generator operate for a short
while until the water level falls to the low water level, check that the water inlet valve
opens automatically and the water inlet indicator LED turns red. Cold water then
enters the boiler and the steam generator starts to produce steam once the high water
level is reached. The water inlet valve will close and the LED will turn green.
6. The timer will then count down to show the remaining time and when it reaches 0 the
steam generator will stop.
7. Once the steam generator has operated for 10 minutes or more and turns off
(manually or automatically) it prepares for automatic drain down cycle. Once the
0
temperature of the water falls below 80 C, drain and flush are carried out and
steaming can begin.
On
On
Off
Off
On
Off
5.1 Steaming Control
The water will only start draining once the temperature has
fallen below 80
℃
.
NOTE