Ÿ
For quick time adjustment hold the “ “ or “ “ and it will count continuously up or
down, when it reaches the desired time release the button and the time is set.
Ÿ
To adjust temperature
:
press “ “ once after setting the time or otherwise twice the
temperature window will flash, enter the required temperature by pressing ” “ or
“ “ to adjust - every press will increase or reduce by 1
℃
. The temp can be adjusted
from 50
℃
-110
℃
once the required temperature has been set press “ “ key the
window will stop flashing.
Model
Enter
SET
When used in commercial situations such as public buildings where the countdown timer is
set to come on in advance the door interlock switch must be connected as described in Fig
12 – before the timer is set to come on in advance the sauna room must be checked by the
operator to ensure there is no hazard such as combustible material left over the sauna stove
or in the sauna – then the sauna cabin door must be closed before the timer setting can be
made – if the timer begins when the door is opened, the controller will cancel the
countdown and won’t operate until reset.
5.3 Door Interlock
6. TROUBLE SHOOTING GUIDE
Description
1. Check the power supply. If the power
supply indicator LED L1 (red) is on,
check the wire
2. Change the controller
Cause
Solution
Faulty;
1. Power supply
2 . C i r c u i t b o a r d
transformer or faulty
fuse
The sauna is
turned on and
there is no
d i s p l a y o n
control panel.
1. Check the connection
2. Change the controller
1.The sauna heater
h a s n ’ t b e e n
connected
2. There is a problem
with the controller
The controller
is on but the
sauna heater
doesn’t work
1. Check the connection to temperature
sensor
2. Check if the high temperature cut off
switch is turned off, if yes ,reset manually
1 . T h e t e m p e r a t u r e
sensor hasn’t been
connected correctly
2. The high temperature
cut off switch is turned
off
O v e r H e a t
LED is on