14
Ÿ
The outlet vent should be placed diagonally opposite to the inlet. It is advisable that the
outlet vent is placed under the platform in sauna room as far as possible from the inlet
vent.
Ÿ
It can be installed near the floor, or from the floor through to a vent to the sauna ceiling,
or under the door (to the wash room).
In this case, the sill slot must be at least 5cm and it is recommended there is mechanical
ventilation in washroom with twice the size of the inlet.
1. Air supply vent
2. Optional air supply vent if mechanical exhaust ventilation is used, the opening is located
50cm above the heater
3. Exhaust air vent
4. Drying vent, which is closed during heating and bathing, the sauna room can also be
dried by leaving the door open after bathing
5. If there is only an exhaust vent in washing room, leave an opening (Min 5cm), under the
sauna door and install mechanical ventilation
5. OPERATION
Ÿ
Before connecting to the power supply check the sauna heater and make sure there are
no flammable items on or around the heater, Note that on the first use the elements and
stones may smoke slightly and give off a smell – ensure the sauna cabin is well
ventilated.
Ÿ
Connect to power supply, press “ “ key, temp and time windows will display data, LED
shows the sauna’s heating status when the heating LED is on, the temperature of sauna
room will rise and will achieve the preset temperature (the default settings are 75
℃
/167
℉
, with work time of 2 hours).
5.1 Testing
Fig 15
Various options of vent outlets
Do not bake food in the heater
NOTE