![DAYLIFF DGW 200P Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/dayliff/dgw-200p/dgw-200p_installation-and-operating-manual_3922795009.webp)
6
Selection and handling of the lube oil
Inlet of Lubricant
Set the generator on a level ground, fill the engine oil through the inlet of lubricant.
Recommended Value
Usable Limit
Ÿ
To check the oil level, simply dip the dipstick into the pan. Do not screw the dipstick.
Upper Level (H)
Lower Level (H)
Ÿ
Nothing affects the performance and durability of generator more than the lube oil
used. If inferior oil is used or if it is not changed regularly, the risk of piston seizure,
piston ring sticking and accelerated wear of the cylinder liner, bearing and other
moving components increases significantly. The generator’s life may be seriously
shortened.
NOTE
Oil should rst be changed after one month or after operating
for 20 hours and thereafter every 3 months or 100 hours.
Ÿ
Be sure to check the oil level and to refill with oil to the specified level before starting
the generator, even though it is equipped with a low oil pressure warning system.
Ÿ
Be sure to drain the oil while the engine is warm. It is difficult to drain the oil completely
after cooling.
WARNING
The changed oil can not be used again, else damage will occur.