![DAYLIFF DGW 200P Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/dayliff/dgw-200p/dgw-200p_installation-and-operating-manual_3922795005.webp)
2
DIMENSIONS & WEIGHTS
ELECTRICAL DATA
Alternator:
self exciting, 2 pole
Power Output:
50Hz, 240V, single phase
AC Power Output:
2 No. Plug DC Terminal Bindings for Welding Cables
Voltage Regulator:
AVR
Power Factor:
1
Speed:
3000rpm
Welding Performance
No Load
Voltage (V)
Operation
Voltage (V)
Operating
Current (A)
62-68
75-80
22-26
22-32
50-130
50-270
Welding Rod Currents (A)
2.5mmØ
50-100
3.2mmØ
100-160
DGW200P
5mmØ
160-180
180-300
DGW200D
WELDING DATA
Max. Arching
Current (A)
200
180
300
Model
DGW300D
4mmØ
SPECIFICATIONS
Engine
Output
Fuel
Tank
Capacity
(litres)
Operating
Period
(Hrs)
Starter
Model
Capacity
(cc)
Rated
Power
(HP)
Rated
(kVA)
Max
(kVA)
DGW 200P
420
418
954
10.5
7.7
17
4.5
685
520
625
107
3.0
800
1070
525
578
600
668
130
195
5
3.3
25
25
12.5
8
6
DGW 200D
Weight
(kg)
Dimensions (mm)
L
W
H
Engine
Model
GK420
LA186FA
LA290F
Electric
DGW 300D
All dimensions in mm
Weight: 100kgs
DERATING:
Given outputs are sea level ratings. Sets should be derated at 1% for every
0
0
100m higher than 100m above sea level, and 2% for every 5 C temperature above 20 C.
H
L
W
Open Frame Type
-
-
Содержание DGW 200P
Страница 1: ...DGW Installation Operating Manual Welding Generator...
Страница 2: ......
Страница 26: ......
Страница 27: ......
Страница 28: ...INS302H 11 22...