background image

will be a beep sound from the buzzer meaning the data has been sent. (Buzzer will be updated in the latest

version)

EVENT

PRE-CONDITION

ACTION

LED STATUS

BUZZER STATUS

ACTIVITIES

POST-
CONDITION

FORCE_DATA

Any state

Move Magnet Key
to contact point of
REED SWITCH.
Buzzer beep 1
time, move
Magnet Key away.

Blink SKY BLUE

Beep 1 time

See FW specs

Back to previous
state

PARAMETERS_UPDATE

Any state

Move Magnet Key
to contact point of
REED SWITCH.
Buzzer beep 1
time, hold Magnet
Key 5s.
Buzzer beep 2
times.

Blink PURPLE

Beep 2 times

See FW specs

Back to previous
state

 Whenever the data is sent to base station, the LED will lit with color codes as below:

RC1: 

RED

 colour

RC2: 

GREEN

 colour

RC4: 

BLUE

 colour

NOTE:

Once sending the data to base station by the magnet key, the timer of sending time interval will be reset;

The shortest time interval between the two manual triggers is 15s. if shorter than 15s, there will be no data

sending.

5.1 LED meaning

Содержание Sigfox WSSFC-PPS

Страница 1: ...Pressure Sensor Internal antenna range 0 10 barg accuracy 0 5 process connection G1 4 male 304SS Type AA battery 1 5VDC IP67 RC1 RC6 RC7 zones STEP 1 Select RC 1 Select RC zone RC zones selection 1 2 4 is RCZ1 RCZ2 RCZ4 refer to section 5 STEP 2 Check ID and PAC Use Modbus Configuration Cable to read the ID and PAC values Refer to register address 8 and 10 DEC USER GUIDE FOR SIGFOX NODE PROCESS PR...

Страница 2: ...B 2022 Update information WSSFC PPS is a Sigfox node integrated Process Pressure Sensor and it has different kinds of measurements such as Gage Absolute Sealed Gage range 1 700 bar high accuracy and stability The sensor will transmit data in kilo meters distance to Sigfox basestation WSSFC PPS can support all regions of Sigfox network in over the World RC1 RC2 RC3 RC4 RC5 RC6 RC7 SENSORS SPECIFICAT...

Страница 3: ...Standard G1 4 or Others consult factory Sigfox SPECIFICATION Sigfox zones select RC2 RC3 RC4 RC5 or RC1 RC6 RC7 Antenna Internal Antenna 2dbi Battery 02 x AA Type 1 5VDC working time up to 10 years depends on configuration RF Module complies to CE FCC ARIB Working temperature 40oC 60oC using Energizer Lithium Ultimate AA battery Dimensions H180xW50xD40 Net weight 250 grams Housing Polycarbonate PO...

Страница 4: ...d was out off the threshold values Lo or Hi called alarm and the number of times of alarm did not pass the limit of number of alarms then it will send data to Base station immediately 2 When the sending time interval is reached it will send data to Base station immediately regardless of value 3 By using the magnet key the Sigfox node can be triggered to send data to base station immediately There ...

Страница 5: ...RAMETERS_UPDATE Any state Move Magnet Key to contact point of REED SWITCH Buzzer beep 1 time hold Magnet Key 5s Buzzer beep 2 times Blink PURPLE Beep 2 times See FW specs Back to previous state Whenever the data is sent to base station the LED will lit with color codes as below RC1 RED colour RC2 GREEN colour RC4 BLUE colour NOTE Once sending the data to base station by the magnet key the timer of...

Страница 6: ...o configure After pressing if theBlue LED blinks once it is Radio Configuration 1 After pressing if the Blue LED flashes twice it is Radio Configuration 2 After pressing if theBlue LED flashes 4 times it is Radio Configuration 4 There are 3 ways to exit the menu Press and hold for 3s the LED turns off to exit the menu Wait 30 seconds then exit the menu Take out the battery it all starts over outsi...

Страница 7: ... on 3 different frequencies Maximum On time 400 ms per channel No new emission before 20 s Listen Before Talk Devices must verify that the Sigfox operated 200 kHz channel is free of any signal stronger than 80 dBm before transmitting Sigfox s high limit EIRP recommendation is included in each column although regulations sometimes allow for more radiated power than the Sigfox recommendation Sigfox ...

Страница 8: ...Step 3 Click New Select a group Step 4 Fill in the required information ...

Страница 9: ...text as shown below Check the box as shown below to register as a prototype Note Some of our products may not have end product certification in time to add the product to Backend Sigfox please follow the steps below ...

Страница 10: ...rtain time to finish the measurement Once reading the value it can be scaled to any engineering value by the following formula Y aX b Where X the raw value from sensor Y the calculated value will be sent to Sigfox base station in the payload data a constant default value is 1 b constant default value is 0 So if there is no user setting fora and b Y X The Y value will be compared with Lo and Hi thr...

Страница 11: ...ays 0b111 every 240h 10 days 0b011 every 24h 1 day 3 MEASURE_PERIOD Period of time to measure sensor 0b0000 every 1s 0b0001 every 2s 0b0010 every 5s 0b0011 every 10s 0b0100 every 20s 0b0101 every 30s 0b0110 every 1min 0b0111 every 2min 0b1000 every 5min 0b1001 every 10min 0b1010 every 20min 0b1011 every 30min 0b1100 every 1h 0b1101 every 2h 0b1110 every 3h 0b1111 every 6h 0b1001 every 10min 4 TX_R...

Страница 12: ...LARM Alarm 0b00 no alarm 0b01 low alarm 0b10 high alarm 0b11 not used 2 BATTERY_LEVEL Battery level 2 bit unsigned integer 0 3 2 RAW_VALUE Raw value of pressure sensor 12 bit 16 bit unsigned integer 16 PRESSURE Scaled value of pressure sensor 32 bit float 32 TENTATIVE Tentative number 8 bit unsigned integer Formula 8 bit_Tentative 1 real_tentative Range 1 to 256 Accuracy 1 Example 0b00000111 0x7 7...

Страница 13: ...ESSURE 9 0 bits 4 1 3 2 2 4 16 32 Value 0b0100 4 yes zeros yes yes zeros yes yes ALARM led blink RED Payload EVENT_ID HW_ERROR reserved ALARM BATTERY_LEVEL reserved RAW_VALUE PRESSURE 9 0 bits 4 1 3 2 2 4 16 32 Value 0b0101 5 yes zeros yes yes zeros yes yes User can set the down link data in Sigfox back end system in advance whenever the Sigfox node connected to base stations and with downlink wai...

Страница 14: ..._TYPE 5 Payload PRM_ADDRESS PRM_LENGTH PRM_VALUE reserved DOWNLINK_TYPE 8 0 bits 8 8 16 28 4 Value yes 0x02 2 yes zeros 0b0101 5 Payload PRM_ADDRESS PRM_LENGTH PRM_VALUE reserved DOWNLINK_TYPE 8 0 bits 8 8 32 12 4 Value yes 0x04 4 yes zeros 0b0101 5 Please pay attention when send downlink data If there was a mistake in sending wrong data it would cause the Sigfox node not working properly and user...

Страница 15: ...https filerun daviteq com wl id qK0PGNbY1g1fuxTqbFW9SXtEvCw7bpc6 Step 2 Plug the configuration cable to computer viaUSB port and install the driver Step 3 Open the housing Serial port configuration on computer 9600 baud None parity 1 stop bit Reading data by Function 3 Writing data by Function 16 NOTE The Modbus configuration can be done in the first 60s after power up the Sigfox node After 60s if...

Страница 16: ...tep 5 Import the configuration file by importing the csv file Go to MENU FILE Import New select the file with name CONFIGURATION TEMPLATE FILE FOR SIGFOX FW1 9 3 csv in the link below Then click Connect CONFIGURATION TEMPLATE FILE FOR SIGFOX WSSFC PPS csv ...

Страница 17: ...Default Format Property Comment 270 10E 3 16 4 CURRENT_CONFIGURATION hex Read Write 274 112 3 16 1 SERVER_CONFIG uint16 Read Write 0 Send to Sigfox Network 1 Send to Dongle 276 114 3 16 1 RADIO_CONFIG 1 2 4 4 uint16 Read Write RC zones selection 1 2 4 is RCZ1 RCZ2 RCZ4 277 115 3 16 1 TX_POWER 20 int16 Read Write RF Tx power 278 116 3 16 2 CONSTANT_A 1 float Read Write Constant a for scaling measur...

Страница 18: ...To maximize the distance of transmission the ideal condition is Line of sight LOS between the Sigfox sensor and 7 Installation 7 1 Locate the good place for Radio signal ...

Страница 19: ... or its antenna inside a completedmetallic box or housing because RF signal can not pass through metallic wall The housing is made from Non metallic materials like plastic glass wood leather concrete cement is acceptable 7 2 Process mounting WARNINGS 1 Please make sure the fluid is suitable with the wetted materials of the sensor Please refer sensor specification 2 Please make sure the operating t...

Страница 20: ...rocess connector The metal tubing and fitting materials and size must be sizing properly to suit the process conditions It is better to install the isolation valve next to sensor process connector Step 1 Using L hex key to unscrew M4 screws at the side of the housing and carefully pull out the top plastic housing in the vertical direction 7 2 2 Remote mounting on wall or pole 7 3 Battery installat...

Страница 21: ...y Step 4 Insert the top plastic housing and locking by L hex key ATTENTION REVERSED POLARITY OF BATTERIES IN 10 SECONDS CAN DAMAGE THE SENSOR CIRCUIT ATTENTION When reinstalling the cover pay attention to put the PCB edge into the middle slot of the box inside as shown below ...

Страница 22: ...etic switch LED does not blink Magnetic switch has malfunctioned Read the status of the magnetic switch via modbus when powering or attaching the battery to see if the magnetic switch is working 4 Node has blinked LED when sending RF but the base station cannot received Out of the number of RF packages per day 140 packages day Check on the base station whether the event message exceeds the number ...

Страница 23: ...r Daviteq Technologies Inc No 11 Street 2G Nam Hung Vuong Res An Lac Ward Binh Tan Dist Ho Chi Minh City Vietnam Tel 84 28 6268 2523 4 ext 122 Email info daviteq com www daviteq com Distributor in Australia and New Zealand Templogger Pty Ltd Tel 1800 LOGGER Email contact templogger net Revision 4 Created Sat Apr 2 2022 4 05 AM by Kiệt Anh Nguyễn Updated Mon Apr 4 2022 1 52 AM by Kiệt Anh Nguyễn 9 ...

Отзывы: