manualshive.com logo in svg
background image

 

H

 

A R D W A R E

 

  I

 

N S T A L L A T I O N

 

Typical Phone Modem Installation

 

8

 

12. Set the Baud rate on the Vantage Pro console. 

 

Enter Setup on the console by pressing and holding the DONE key, then press-
ing the DOWN arrow key. Use the BAR and DONE keys to scroll through the 
setup screens until you reach the BAUD RATE setup screen.

 

Note:

 

The Baud Rate setup screen will only appear if you have installed the data logger. 

 

 

Use the up and down arrows to set the desired Baud rate. 

 

Use the fastest Baud rate your modem can handle. 19200 is the fastest
Baud rate available and is the default setting on the console.

 

 

Press DONE when you’ve got the correct Baud rate on the console screen.

 

Pressing DONE in this screen sends the initialization string to the modem,
so you don’t have to turn the console on and off again.

 

A Few Notes About Phone Modem Connections

 

If you indicate a phone modem connection when setting up your station, the soft-
ware automatically dials the station whenever you initiate a program action that 
requires the software to talk to the station.

While connected to a phone modem station, an “On-Line” icon appears in the 
toolbar. This icon indicates that you are on-line and may be used to hang up a 
remote connection. To hang up, choose the On-Line icon from the toolbar or 
choose Hang Up from the File menu.

 

T

 

OOLBAR

 

 

 

WITH

 

 O

 

N

 

-L

 

INE

 

 I

 

CON

 

By default, WeatherLink will hang up the connection to the modem after one 
minute without any communication with the station. Use the Serial Port dialog 
box in the Setup menu of WeatherLink to change this default value. (See the 
WeatherLink help files for more on this subject.) 

 

Note:

 

WeatherLink will not hang up the phone line if the Bulletin or Summary windows are active. 

Содержание and Vantage Pro

Страница 1: ...Getting Started Guide WeatherLink Vantage ProTM Product 6510 For...

Страница 2: ...r more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from...

Страница 3: ...ct Davis Instruments technical support at 510 732 7814 Loopback connector The loopback connector is a short piece of cable with a phone plug at one end and a red plastic cap at the other The loopback...

Страница 4: ...ry for the data files depends on the archive inter val Database files containing data stored at a 30 minute archive interval require approximately 36K of disk space per month of data The file size cha...

Страница 5: ...logger may cause damage to the data logger or console 3 Carefully insert the data logger into the large receptacle jack marked EXPANSION inside the battery compartment Guide the data logger cable thro...

Страница 6: ...eatherLink s bul letin summary or real time strip charts if the console is attached to the computer 8 Check the Baud rate settings on the console Enter the console SETUP mode by pressing and holding t...

Страница 7: ...he battery cover from the console back and remove all power by removing the batteries and AC power adapter if present Failure to remove power to the console before installing the data logger may cause...

Страница 8: ...have to turn the console on and off again A Few Notes About Phone Modem Connections If you indicate a phone modem connection when setting up your station the soft ware automatically dials the station...

Страница 9: ...with your station you must add your station to WeatherLink s database which means naming the station configuring the software to work with that station and with your computer hardware and setting stat...

Страница 10: ...Set Barometer Elevation Set the barometric pressure and your elevation on the station and on the soft ware Set Rain Calibration Set the station s rainfall calibration number Set Temperature and Humid...

Страница 11: ...ocedure for locating the serial port to which your sta tion is connected or determining whether that serial port is working Using the Loopback command as opposed to Test will help you find the correct...

Страница 12: ...d serial ports and inform you of the COM port at which the loopback connector is located The software automatically selects the correct COM port for you in the Serial Port dialog box If it cannot find...

Страница 13: ...he first beep tells you the processor is running The second beep will be for the logger if installed and the third beep is for the display If you do not hear one or more of these beeps contact Davis I...

Страница 14: ...e time and date on the weather station are correct I have duplicate records in my database Why If you do not download from the data logger prior to changing the weather station s time and date for a D...

Страница 15: ...ower to the sta tion Note Make sure to put the console in Setup Mode by pressing the DONE and DOWN arrow keys before removing the batteries The ensures the station will not try to write any data when...

Страница 16: ...lose Window F1 Context Sensitive Help F2 Sunrise Sunset Report F7 NOAA This Month F8 NOAA This Year Strip Chart Window ESC Halt redraw Ctrl M Make Default Ctrl P Print Strip Chart F1 Context Sensitive...

Отзывы: