DAVIS AirLink 7210 Скачать руководство пользователя страница 2

0

FCC Part 15 Class B Registration Warning

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 

equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any 
interference, including interference received, including inference that may cause undesired operation.
If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment on and off, the user is encouraged to try to correct the 
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.

Consult the dealer or an experienced radio/TV technician for help.

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to 
the following two conditions: (1) this device may not cause interference, and (2) this device must 
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio 
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit 
pas produire de brouillage, et (2) l'appareil doit accepter tout brouillage radioelectrique subi, même si 
le brouillage est susceptible d'en compromettre le fonctionnement.
Innovation, Science and Economic Development Canada ICES-003 Compliance Label: CAN ICES-3 
(B)/NMB-3(B)
Changes or modification not expressly approved in writing by Davis Instruments may void the warranty 
and void the user's authority to operate this equipment.
Contains: FCCID: 2AC7Z-ESP32WROVERE   IC: 21908-ESP32WROVERE

Information Regarding Exposure to Radio Frequency Energy: 

The antenna used for this 

transmitter must be installed to provide a separation distance of at least 20 cm from all persons and 
must not be co-located or operating in conjunction with any other antenna or transmitter.

Davis Instruments, 3465 Diablo Ave., Hayward, CA 94545

Power Supply Model identifier: DSA-5PF07-05 FUK 050100 or DSA-5PF07-05 FEU 05010

EC-Declaration of Conformity

Directive 2014/53/EU (RED)

Manufacturer/responsible person:

Davis Instruments 
Compliance Engineer
3465 Diablo Ave., Hayward, CA 94545 USA

Declares that the products:

7210EU, 7210UK, 7210USB

Comply with the essential requirements of 

2014/53/EU, if used for its intended use. The complete Declaration of Conformity is on our website at 
https://www.davisinstruments.com/legal.
The technical documentation relevant to the above equipment will be held at:
Davis Instruments at 3465 Diablo Ave, Hayward CA 94545.
RoHS Compliant.

Input voltage:

100-240 VAC 

Input AC frequency: 

50/60 Hz 

Output voltage:

5.0 VDC 

Output current: 

1.0 A 

Output power: 

5.0 W 

Average active efficiency:

73.77% 

Efficiency at low load (10 %): 

N/A % 

No-load power consumption 

0.075 W

Содержание AirLink 7210

Страница 1: ...Air Quality Sensor Product number 7210 USER MANUAL AirLink Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisinstruments com R TM R R ...

Страница 2: ...eration of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage radioelectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Innovation Science ...

Страница 3: ... may choose your preferred Air Quality Index AQI from a growing list United States Air Quality Index Air Quality Health Index Canada Metropolitan Index of Air Quality Index Mexico Common Air Quality Index EU UK Daily Air Quality Index India Air Quality Index China Individual Air Quality Index AIRKOREA South Korea Australian Air Quality Index 6 hour Air Quality Chart High AQI NowCast reading NowCas...

Страница 4: ...ion Wi Fi password Phone with Bluetooth enabled AC power Drill or screwdriver if mounting on a vertical surface Power Cable plug in adapter not included in USB version Mounting Screws Foot Pads Sensor Cover Mounting Bracket attached to back of sensor housing R Sensor Housing R ...

Страница 5: ...near your AirLink sensor tap the Account icon in the upper right corner of the app s home screen 5 Tap the Add button next to Devices then choose AirLink Note You will use the user name and password you have set up to access your page on WeatherLink com from your computer as well You will only have to enter your name and password the first time you open the app unless you log out The WeatherLink a...

Страница 6: ... will be entered automatically 2 In the next screen a map opens with the location of your station You can change this by moving the pin Tap Save 3 In the next screens select your Wi Fi network and enter the network password Tap Connect 4 Your air quality data will now appear in the opening snapshot screen of the WeatherLink app and on your bulletin page on WeatherLink com Your AirLink s name will ...

Страница 7: ... Choose a shaded and protected spot In the Northern Hemisphere a north facing south facing in the Southern Hemisphere wall or under an eave is a good choice Don t install the sensor near outdoor exhaust vents for air conditioning hot water heaters dryers or kitchen bathroom vents Note If using outdoors mount only on a vertical surface and with the outdoor sensor cover Do not use on a flat surface ...

Страница 8: ...6 4 If installing outside slide the sensor cover over the sensor housing R R ...

Страница 9: ...the board You should ground yourself before opening the case by touching any conductive material such as metal that is either touching the floor or touching a series of items leading to the floor 1 Unplug the AC power cable Note Unplugging the AC adapter will cause any stored archive data to be lost Since data is uploaded as soon as it is generated when connected to Wi Fi this will only be a probl...

Страница 10: ...7 about possible archive data loss from power loss My AirLink will not connect to the internet Check to make sure you entered the correct Wi Fi password You may have entered the wrong password repower the AirLink and try reconfiguring Wi Fi in the app There is no air quality data on my WeatherLink com page and app Make sure the sensor is powered up and connected to the internet Can I change my arc...

Страница 11: ...t Davis Technical Support We ll be glad to help Online www davisinstruments com See the Weather Support section for copies of user manuals product specifications application notes software updates and more E mail support davisinstruments com Telephone 510 732 7814 Monday Friday 7 00 a m 5 30 p m Pacific Time ...

Страница 12: ...ormation Operating Temperature 14 to 140 F 10 to 60 C Storage Temperature 40 176 F 40 80 C Current Draw Average 100 mA Peak 500mA Housing Material Rugged ABS Plastic AC Adapter not included with 7210USB 5 VDC 1000 mA Wi Fi Frequency Range US Model 2412 2462 MHz 802 11b g n EU UK USB Models 2412 2472 MHz 802 11b g n BLE Frequency Range 2402 2480 MHz Particulate Matter Sensor Particle Range of Measu...

Отзывы: